1 / 1
thumbnail

Opis

TeSys LRD thermal overload relay, 10A/690V, thermal setting range 7-10A, tripping class 20, for protection of 3-phase motors 4kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B105 (to be ordered separately). Multi standards certified (IEC, UL, CSA, Marine), Green Premium compliant (RoHS/REACh).
Country of Origin
FR
Part Number
LRD1514
Tariff Code
85364900
EAN
3389110146721
UNSPSC
39122330
£68.63
net
1
Metody płatności:
Najlepsza oferta od:
GBZaufany dostawca Automa.Net
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 08-11-2024
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Fabrycznie Nowe, Zapieczętowane - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Łącznie 59 części w magazynie od 14 dostawców
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Dostępne Oferty (14)

LRD1514 product image
Schneider Electric

LRD1514

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 08-11-2024
Oferta od:
ITZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€77.40
net
LRD1514 product image
Schneider Electric

LRD1514

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 08-11-2024
Oferta od:
ESZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€88.73
net
LRD1514 product image
Schneider Electric

LRD1514

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 08-11-2024
Oferta od:
FRZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€96.90
net
LRD1514 product image
Schneider Electric

LRD1514

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 09-11-2024
Oferta od:
NLZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€101.52
net
LRD1514 product image
Schneider Electric

LRD1514

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 08-11-2024
Oferta od:
DEZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€151.00
net
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
€24.01

Specifications

Network Type
AC || DC
Thermal Protection Adjustment Range
7-10 A
Relay Application
motor protection
Product Or Component Type
differential thermal overload relay
Product Name
TeSys LRD || TeSys Deca
Thermal Overload Class
class 20 IEC 60947-4-1
Range
TeSys
[Ui] Rated Insulation Voltage
power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Product Compatibility
LC1D09 || LC1D32 || LC1D25 || LC1D18 || LC1D12
Device Short Name
LRD

Contractual warranty

Warranty
18 months

Complementary

Network Frequency
0...400 Hz
[Ith] Conventional Free Air Thermal Current
5 A signalling circuit
Auxiliary Contact Composition
1 NO + 1 NC
Connections - Terminals
control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit screw clamp terminals 1 1.5-10 mm² flexible without cable end || power circuit screw clamp terminals 1 1-4 mm² flexible with cable end || power circuit screw clamp terminals 1 1-6 mm² solid without cable end
Phase Failure Sensitivity
tripping current 130 % of Ir on two phase, the last one at 0
[Ue] Rated Operational Voltage
690 V AC 0...400 Hz power circuit IEC 60947-4-1
Associated Fuse Rating
4 A gG signalling circuit || 4 A BS signalling circuit
Net Weight
0.19 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV
Permissible Current
1.5 A 240 V AC-15 signalling circuit || 0.1 A 250 V DC-13 signalling circuit
Tripping Threshold
1.14 +/- 0.06 Ir IEC 60947-4-1
Tightening Torque
control circuit 1.7 N.m screw clamp terminals || power circuit 1.85 N.m screw clamp terminals
Control Type
Red push-button stop || Blue push-button reset
Mounting Support
plate, with specific accessories || rail, with specific accessories || under contactor
Width
45 mm
Depth
92 mm
Temperature Compensation
-20-60 °C

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP080206EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc
Yes
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
ENVEOLI0802006
Eu Rohs Directive
Compliant

Environment

Product Certifications
IEC || UL || CSA || EAC || DNV-GL || LROS (Lloyds register of shipping)
Mechanical Robustness
vibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7
Standards
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1
Climatic Withstand
IACS E10
Ambient Air Temperature For Operation
-20-60 °C without derating IEC 60947-4-1
Dielectric Strength
1.89 kV 50 Hz IEC 60947-1
Ip Degree Of Protection
IP20 conforming to IEC 60529
Flame Retardance
V1 conforming to UL 94
Ambient Air Temperature For Storage
-60-70 °C
Fire Resistance
850 °C IEC 60695-2-1

Modele CAD

traceparts
traceparts
Pobierz