EasyLogic PM2210, Power & Energy meter, Total Harmonic, LCD display, Pulse, class 1
METSEPM2210
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
€113.18
1
Metody płatności:
Łącznie 23 części w magazynie od 16 dostawców
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
Wyślij zapytanie o cenę

Additional Information

Part Number
METSEPM2210
UNSPSC
41113708
Tariff Code
9030390100
Country of Origin
US

Environment

Ambient Air Temperature For Operation
-10-60 °C
Electromagnetic Compatibility
electrostatic discharge conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || surge immunity test conforming to IEC 61000-4-5 || conducted RF disturbances conforming to IEC 61000-4-6 || magnetic field at power frequency conforming to IEC 61000-4-8 || voltage dips and interruptions immunity test conforming to IEC 61000-4-11 || emission tests conforming to FCC Part 15 class A
Pollution Degree
2
Ambient Air Temperature For Storage
-25-70 °C
Relative Humidity
5-95 % 50-50 °C
Service Life
7 year(s)
Ip Degree Of Protection
front IP54 IEC 60529 || body IP30 IEC 60529
Overvoltage Category
III
Operating Altitude
<= 6561.68 ft (2000 m)

Complementary

Network Frequency
60 Hz || 50 Hz
Output Voltage
20 ms 5...40 V DC, 20 mA 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Power Quality Analysis
total harmonic distortion
Height
96 mm
Measurement Voltage
35-480 V AC 50/60 Hz between phases || 20-277 V AC 50/60 Hz between phase and neutral || 480-999000 V AC 50/60 Hz with external VT
Sampling Rate
64 samples/cycle
Maximum Power Consumption In W
3.3 W power lines (AC)) || 2 W 277 V power lines (DC))
Number Of Outputs
1 pulse
User Language
German || English || Chinese || Russian || Spanish || Portuguese || French
Product Certifications
CE IEC 61010-1 || cULus UL 61010-1 || cULus CSA C22.2 No 61010-1 || RCM || EAC || C-tick
Type Of Measurement
apparent power min/max, total || active and reactive power min/max, total || current min/max, avg || voltage min/max, avg || frequency min/max, avg || total current harmonic distortion THD (I) per phase || total voltage harmonic distortion THD (U) per phase || power factor min/max, avg || apparent energy total || active and reactive energy total
Communication Port Protocol
POP
Frequency Measurement Range
45-65 Hz
Communication Service
remote monitoring
Display Resolution
128 x 128 pixels
Number Of Inputs
0
Material
polycarbonate
Net Weight
300 g
Tamperproof Of Settings
protected by access code
Provided Equipment
1 x Installation guide
Depth
total 76.09 mm || embedded 61.64 mm
Measurement Current
5-6000 mA
Local Signalling
Red LED output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) || Green LED module operating (RUN)
Connections - Terminals
current transformer screw connection bottom) 6 || voltage inputs screw connection top) 4
Information Displayed
demand current past value) || demand current present value) || demand power past value) || demand power present value) || voltage || current || frequency || energy consumption || harmonic distortion || power factor || active power || apparent power || reactive power || unbalanced in % || harmonic amplitude
Electrical Insulation Class
class II || double insulation
Control Type
4 x button
Flame Retardance
V-0 conforming to UL 94
[Us] Rated Supply Voltage
44...277 V AC 45...65 Hz +/- 10 % || 44...277 V DC +/- 10 %
Impulse Duration
20 ms
Mounting Mode
clip-on
Measurement Accuracy
apparent power +/- 1 % || active energy +/- 1 % || reactive energy +/- 1 % || active power +/- 1 % || voltage +/- 0.5 % || power factor +/- 0.01 || current +/- 0.5 % || frequency +/- 0.05 %
Mounting Support
framework
Compatibility Code
PM2210
Refresh Time
configurable from 1 to 60 min
Line Rated Current
1 A || 5 A
Cybersecurity
enable/disable communication ports
Display Colour
monochrome
Analogue Input Type
current (impedance <= 0.3 mOhm) || voltage (impedance > 5 MOhm)
Mounting Position
vertical
Width
96 mm
Display Type
Backlit LCD
Measurement Category
category III 480-480 V || category II 480-600 V
Device Application
sub billing || power monitoring
Metering Type
voltage U, U21, U32, U13, V, V1, V2, V3 || unbalance current || calculated neutral current || apparent power S, S1, S2, S3 || peak demand currents || current I, I1, I2, I3 || active, reactive, apparent energy (signed, four quadrant) || active power P, P1, P2, P3 || reactive power Q, Q1, Q2, Q3 || peak demand power PM, QM, SM || demand power P, Q, S
Accuracy Class
class 1 active energy IEC 62053-21 || class 1 reactive energy IEC 62053-24
Maximum Power Consumption In Va
6 VA 277 V AC

Specifications

Product Or Component Type
power meter
Product Name
EasyLogic PM2200
Range
EasyLogic
Device Short Name
PM2210

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1510004
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation
X
Circularity Profile
ENVEOLI1510004
Eu Rohs Directive
Compliant with Exemptions

Dokumenty

Data Sheet

Pobierz