Schneider Electric
NSYTRR42SCAR
1 / 1
Opis
Końcówka Serii
- Part Number
- NSYTRR42SCAR
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Specifications
- Mounting Mode
- clip-on
- Terminal Block Level
- 1
- Terminal Block Type
- blade disconnect
- Nominal Cross Section
- 4 mm²
- Quantity Per Set
- set of 50
- Product Or Component Type
- terminal block
- Color
- Orange
- Product Name
- Linergy TR
- Length
- 57.8 mm
- Device Short Name
- TRR
- Range
- Linergy
Complementary
- Dielectric Loss
- 0.01 at 1 MHz IEC 60250 || 0.01 at 1 MHz VDE 0303-T4
- Wire Stripping Length
- 9 mm
- Resistivity
- 10000 MΩ.m IEC 60093 || 10000 MΩ.m VDE 0303-T30
- Height
- 49.1 mm
- Number Of Terminals
- 2
- Cable Cross Section
- 0.14-6 mm², flexible without cable end || 0.14-6 mm², solid
- Connections - Terminals
- 1 x spring terminal upstream || 1 x spring terminal downstream
- Dielectric Constant
- 3.7 at 1 MHz
- Material
- polyamide 6/6 insulating case
- Connection Position
- sideways
- Number Of Measurement Input
- 2
- Surface Resistance
- 1000 GΩ IEC 60093 || 1000 GΩ VDE 0303-T30
- Width
- 6.2 mm
- Range Compatibility
- Prisma G || Prisma P || Prisma PH || Prisma Pack || Spacial || Kaedra || Pragma || TeSys
- Product Compatibility
- Spacial enclosures
- Line Rated Current
- 20-20 A EN/IEC 60947-7-1 || 16-16 A CSA || 16-16 A cURus
- Tool Type
- connection screwdriver || disconnection screwdriver
- Net Weight
- 13.7 g
- Flame Retardance
- V0 0.8 mm UL 94
- Creep Resistance
- 500 CTI (> 400 kB) IEC 60093 || 500 CTI (> 400 kB) VDE 0303-T30
- [Ue] Rated Operational Voltage
- 500 V EN/IEC 60947-7-1 || 600 V CSA || 600 V cURus
Offer Sustainability
- China Rohs Regulation
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1304013EN
- Sustainable Offer Status
- Green Premium product
- Toxic Heavy Metal Free
- Yes
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- Reach Free Of Svhc
- Yes
Environment
- Product Certifications
- EAC || cURus
- Ambient Air Temperature For Operation
- -40-130 °C IEC 60216-1 || -40-130 °C VDE 0304-T21
- Dielectric Strength
- 1000 V IEC 60243-1
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne