Roof Top Unit, Heat Pump & Indoor Air Quality Ctrl: BACnet MS/TP, RH sensor & control, PIR motion sensor, White Case/Fascia
SE8650U5B11
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Oferta z czasem realizacji przez producenta
Wysyłka:1 - 2 Dni robocze
Najlepsza cena:
€304.53

Additional Information

Part Number
SE8650U5B11
UNSPSC
40101708
Tariff Code
9032100030
Country of Origin
MX

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: LEAD, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Eu Rohs Directive
Compliant with Exemptions

Specifications

Housing Colour
white
Ambient Air Temperature For Operation
0-50 °C
Height
120 mm
Calibration Certificate
1 Pt
Standards
EN/IEC 60730-1 || FCC part 15 Subpart B || ICES-003 || ETSI EN 300 328 || ETSI EN 301 489-1:v1.9.2 || FCC part 15 Subpart C || UL 60730-2-9 || ETSI EN 301 489-17:v2.2.1, 2012
Output Voltage
24 V AC/DC relay output || 0...10 V AC/DC voltage output
Targeted Region
North America.
Product Or Component Type
roof top unit
Output Type
5 xrelay output || 4 xuniversal
Humidity Measurement Drift
Less Than 1 % Yearly
Product Name
SE8000 Series
Net Weight
340 g
Range
EcoStruxure Building Expert
Input Type
dry contact 2 || analog 5
Communication Port Protocol
BACnet MS/TP || Modbus RTU || Zigbee Pro
Directives
2014/30/EU - electromagnetic compatibility || 2014/35/EU - low voltage directive || 2014/53/EU - radio equipment directive
Awg Gauge
AWG 22...AWG 18
Ambient Air Temperature For Storage
-30-50 °C
Output Current
1 A relay output || 3 A relay output inrush) || 0.3 A universal output || 1.5 A universal output inrush)
Input Voltage
0...10 V
Sensor Type
10 kOhm T2 NTC thermistor Temperature || space RH sensor Humidity || bulk polymer Humidity
Relative Humidity
0-75 %
Temperature Setting Range
12-37.5 °C cooling || 4.5-32 °C heating
Width
86 mm
Humidity Setting Range
30-95 %
Market Segment
Lodging/Hotel || small commercial || buildings || healthcare || non-critical buildings || office || residential || school
Temperature Resolution
0.1 °C
Depth
25 mm
Device Application
staging equipment (RTU/HP)
Device Short Name
SE8600

Complementary

Surface Finish
Matte
Surface Treatment
untreated

Dokumenty

Data Sheet

Pobierz