Limit switch, Limit switches XC Standard, XCKD, thermoplastic plastic roller lever var.length, 1NC+1 NO, slow, M16
XCKD2545P16
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
Wyślij zapytanie o cenę

Additional Information

Part Number
XCKD2545P16
UNSPSC
39122213
Tariff Code
8536509055
Country of Origin
ID

Specifications

Type Of Approach
lateral approach, 2 directions
Series Name
standard format
Contacts Type And Composition
1 NC + 1 NO
Movement Of Operating Head
rotary
Body Type
fixed
Range Of Product
Telemecanique Limit switches XC Standard
Contact Operation
slow-break, break before make
Fixing Mode
by the body
Type Of Operator
spring return roller lever thermoplastic variable length
Sensor Design
compact
Body Material
zamak
Product Or Component Type
limit switch
Head Material
zamak
Material
metal
Device Short Name
XCKD
Number Of Poles
2
Head Type
rotary head

Contractual warranty

Warranty
18 months

Complementary

Switch Actuation
by 30° cam
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Height
65-65 mm
Terminals Description Iso N°1
(21-22)NC || (13-14)NO
Short-Circuit Protection
10 A cartridge fuse gG
Electrical Durability
5000000 cycles, DC-13, 120 V, 7 W 60 cyc/mn 0.5 , DC IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 13 W 60 cyc/mn 0.5 , DC IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 9 W 60 cyc/mn 0.5 , DC IEC 60947-5-1 appendix C
Positive Opening
with
Contacts Insulation Form
Zb
Electrical Connection
screw-clamp terminals 1 x 0.5...2 x 2.5 mm²
Positive Opening Minimum Torque
0.25 N.m
Mechanical Durability
10000000 cycles
Maximum Actuation Speed
1.5 m/s
Cable Entry
1 entry tapped for M16 x 1.5 cable gland 4-8 mm
Contact Code Designation
A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN 60947-5-1 || A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN 60947-5-1 || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A IEC 60947-5-1 appendix A
Width
31 mm
Depth
30 mm
Minimum Torque For Tripping
0.1 N.m
Net Weight
0.235 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV IEC 60947-1
Repeat Accuracy
0.1 mm on the tripping points with 1 million operating cycles
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CCC || UL || CSA
Ik Degree Of Protection
IK06 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
IEC 60204-1 || EN 60204-1 || CSA C22.2 No 14 || UL 508 || IEC 60947-5-1 || EN 60947-5-1
Electrical Shock Protection Class
class I IEC 61140 || class I NF C 20-030
Ip Degree Of Protection
IP66IEC 60529 || IP67IEC 60529
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Protective Treatment
TC