1 / 1
thumbnail

Opis

Końcówka Serii
Part Number
XCMH2910L1
Tariff Code
8536509055
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Poproś o wycenę, a prześlemy Ci informacje o dostępności i cenie.

Specifications

Movement Of Operating Head
linear
Range Of Product
Telemecanique Limit switches XC Standard
Fixing Mode
by the body
Type Of Operator
spring return plunger metal
Sensor Design
miniature
Product Or Component Type
limit switch
Head Material
zamak
Material
plastic
Head Type
plunger head
Type Of Approach
vertical approach, 1 direction
Series Name
standard format
Contacts Type And Composition
2 NC
Body Type
fixed
Contact Operation
snap action
Body Material
plastic
Device Short Name
XCMH
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Height
60-60 mm
Short-Circuit Protection
6 A cartridge fuse gG
Minimum Actuation Speed
0.01 m/min
Electrical Connection
fixed cable
Cable Length
1 m
Net Weight
0.08 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV IEC 60664 || 4 kV IEC 60947-1
Switch Actuation
on end
[Ui] Rated Insulation Voltage
300 V 3)UL 508 || 300 V 3)IEC 60947-5-1 || 300 V 3)CSA C22.2 No 14
Electrical Durability
5000000 cycles, DC-13, 120 V, 1 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 3 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 2 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force
42.5 N
Positive Opening
with
Contacts Insulation Form
Zb
Mechanical Durability
5000000 cycles
Maximum Actuation Speed
0.5 m/s
Wire Insulation Material
PvR
Minimum Force For Tripping
8.5 N
Cable Composition
4 x 0.34 mm²
Contact Code Designation
C300, AC-15 (Ue = 240 V), Ie = 0.75 A EN/IEC 60947-5-1 appendix A || R300, DC-13 (Ue = 250 V), Ie = 0.1 A EN/IEC 60947-5-1 appendix A
Width
30 mm
Depth
16 mm
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CCC || UL || CSA
Ik Degree Of Protection
IK04 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/IEC 60947-5-1 || UL 508 || CSA C22.2 No 14 || EN/IEC 60204-1
Shock Resistance
25 gn 18 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class II IEC 61140 || class II NF C 20-030
Protective Treatment
TC

Dokumenty

Data Sheet

Pobierz