1 / 1
thumbnail

Opis

Końcówka Serii
This XCSM Miniature Safety Limit Switch has a thermoplastic roller lever, a Zamak body and head and a 5 meter pre-cabled. It has 2 normally open and 2 normally closed snap action contacts. Its B10D reliability data is 50 000 000. It has IK06 impact resistance and IP66 / IP67 / IP68 degree of protection, makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Country of Origin
ID
Part Number
XCSM4115L5
Tariff Code
85365080
EAN
3389110244328
UNSPSC
39122213
Metody płatności:
Najlepsza oferta od:
DEZaufany dostawca Automa.Net
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 08-11-2024
Gwarancja:
12 miesięcy
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Nowy, Rynek wtórny
Nowy, Rynek wtórny - Nowy, nieużywany, nieuszkodzony przedmiot bez gwarancji producenta. Przedmiot może być dostarczony bez oryginalnego opakowania lub w zastępczym opakowaniu. Jeśli dostarczono, pudełko mogło zostać otwarte.
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Specifications

Contacts Type And Composition
1 NC + 1 NC + 1 NO + 1 NO
Range Of Product
Telemecanique Safety switches XCS
Product Or Component Type
safety limit switch
Protection Technology
plastic protective cover, secured by 5-lobe socket head safety screw
Component Name
XCSM
Design
miniature
Material
metal
Head Type
rotary head
Type Of Approach
lateral approach
Contact Operation
snap action
Type Of Operator
thermoplastic roller lever

Contractual warranty

Warranty
18 months

Complementary

Height
94-94 mm
Short-Circuit Protection
6 A cartridge fuse gG (gl)
Minimum Actuation Speed
0.01 m/min
Repeat Accuracy
0.05 mm on the tripping points
Fixing Mode
by the body
Cable Length
5 m
Head Material
zamak
Net Weight
0.205 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV IEC 60664 || 4 kV IEC 60947-1
Switch Actuation
by 30° cam
[Ui] Rated Insulation Voltage
300 VUL 508 || 400 V 3)IEC 60947-5-1 || 300 VCSA C22.2 No 14
Positive Opening
with NC contact
Positive Opening Minimum Torque
0.1 N.m
Mechanical Durability
10000000 cycles
Maximum Actuation Speed
1.5 m/s
Body Material
zamak
Electrical Connection
pre-cabled
Cable Composition
9 x 0.34 mm²
Contact Code Designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN 60947-5-1 || B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN 60947-5-1 || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A
Width
30 mm
Depth
34 mm
Minimum Torque For Tripping
0.5 N.m
Number Of Poles
4
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110612EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI110612EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA
Ik Degree Of Protection
IK06 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Standards
CSA C22.2 No 14 || UL 508 || EN/IEC 60947-5-1 || EN 1088 || EN/IEC 60204-1
Shock Resistance
25 gn 18 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529 || IP68 conforming to IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I NF C 20-030 || class I EN/IEC 61140
Safety Reliability Data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Protective Treatment
TC
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508