Schneider Electric
XCSMP80L2
1 / 1
Opis
Końcówka Serii
This XCSMP Key Operated Safety Switch for guard doors has a fixed head and a robust red coated polyamide compact body with 2 meter pre-cabled, allowing for flexible installation. It has 3 normally closed simultaneous (slow break) contacts. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.- Country of Origin
- JP
- Part Number
- XCSMP80L2
- Tariff Code
- 8536509065
- EAN
- 39122213
- UNSPSC
- 39122213
Metody płatności:
- Najlepsza oferta od:
- Zaufany dostawca Automa.Net
- Dostępność:
- 1 szt.W magazynieZaktualizowano: 08-11-2024
- Gwarancja:
- 12 miesięcy
- Szacowany czas dostawy:
- Na zapytanie
- Stan produktu:
- Nowy, Rynek wtórny
Nowy, Rynek wtórny - Nowy, nieużywany, nieuszkodzony przedmiot bez gwarancji producenta. Przedmiot może być dostarczony bez oryginalnego opakowania lub w zastępczym opakowaniu. Jeśli dostarczono, pudełko mogło zostać otwarte.
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja
Specifications
- Contacts Type And Composition
- 3 NC
- Range Of Product
- Telemecanique Safety switches XCS
- Electrical Connection
- pre-cabled
- Locking Options Description
- without locking of actuator
- Contact Operation
- slow-break, simultaneous
- Product Or Component Type
- safety switch
- Component Name
- XCSMP
- Material
- plastic
- Design
- miniature
- Number Of Poles
- 3
- Head Type
- key operated fixed head
Contractual warranty
- Warranty
- 18 months
Complementary
- Height
- 87-87 mm
- Maximum Operating Rate
- 20 cyc/mn for maximum durability
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
- Short-Circuit Protection
- 10 A cartridge fuse gG (gl)
- Insulation
- double insulated
- Positive Opening
- with NC contact
- Minimum Actuation Speed
- 0.05 m/s
- [Ie] Rated Operational Current
- 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1 || 1.5 A 120 V, AC-15, C300 EN/IEC 60947-5-1
- Minimum Actuator Force For Extraction
- 8 N
- Mechanical Durability
- 1000000 cycles
- Maximum Actuation Speed
- 1.5 m/s
- Cable Length
- 2 m
- Body Material
- PA (polyamide)
- [Ithe] Conventional Enclosed Thermal Current
- 2.5 A
- Safety Reliability Data
- B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
- Cable Composition
- 6 x 0.5 mm²
- Width
- 15 mm
- Actuator Forcible Withdrawal Rtc
- 8 N
- Depth
- 30 mm
- Head Material
- PA (polyamide)
- Net Weight
- 0.11 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-5-1
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environment
- Product Certifications
- CSA || cUL || UL
- Ambient Air Temperature For Operation
- -25-70 °C
- Ambient Air Temperature For Storage
- -25-80 °C
- Standards
- UL 508 || EN/IEC 60204-1 || EN/ISO 12100 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || EN 1088/ISO 14119
- Electrical Shock Protection Class
- class II EN/IEC 61140
- Shock Resistance
- 50 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 6 gn 10-55 Hz)IEC 60068-2-6
- Protective Treatment
- TC
- Ip Degree Of Protection
- IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1