Safety switch, Telemecanique Safety switches XCS, plastic XCSPA, 1 NC + 1 NO, snap action, 1 entry tapped Pg 11
XCSPA191
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Łącznie 1 część w magazynie od 9 dostawców

Additional Information

Part Number
XCSPA191
Tariff Code
8536509040

Specifications

Range Of Product
Telemecanique Safety switches XCS
Cable Entry
1 entry tapped Pg 11
Electrical Connection
terminal 1 x 0.34...2 x 1.5 mm²
Locking Options Description
without locking of actuator
Product Or Component Type
safety switch
Component Name
XCSPA
Material
plastic
Design
compact
Head Type
key operated turret head
Contacts Type And Composition
1 NC + 1 NO
Contact Operation
snap action
Cable Outer Diameter
7-10 mm
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Height
94-94 mm
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Minimum Actuation Speed
0.01 m/s
[Ithe] Conventional Enclosed Thermal Current
10 A
Head Material
PA (polyamide)
Net Weight
0.11 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Maximum Operating Rate
10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
Positive Opening Minimum Force
15 N
Insulation
double insulated
Positive Opening
with NC contact
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1
Mechanical Durability
1000000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
PA (polyamide)
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Width
30 mm
Actuator Forcible Withdrawal Rtc
10 N
Depth
30 mm
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110606EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI110603EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA
Ambient Air Temperature For Operation
-25-70 °C
Standards
UL 508 || EN/IEC 60204-1 || EN 1088/ISO 14119 || EN/ISO 12100 || EN/IEC 60947-5-1 || CSA C22.2 No 14
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60947-5-1
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class II EN/IEC 61140
Protective Treatment
TC

Dokumenty

Data Sheet

Pobierz

Powiązane produkty