1 / 1
thumbnail

Opis

Końcówka Serii
This XCSTR Safety Limit Switch has a 30 mm stainless steel spindle, a double insulated plastic enclosure and 2 x Pg 11 cable gland entries. It has 2 normally open and 1 normally closed break-before-make (slow break) contacts. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Country of Origin
FR
Part Number
XCSTR551
Tariff Code
85365080
EAN
3389110177183
UNSPSC
39122205
Metody płatności:
Najlepsza oferta od:
DEZaufany dostawca Automa.Net
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 08-11-2024
Gwarancja:
12 miesięcy
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Nowy, Rynek wtórny
Nowy, Rynek wtórny - Nowy, nieużywany, nieuszkodzony przedmiot bez gwarancji producenta. Przedmiot może być dostarczony bez oryginalnego opakowania lub w zastępczym opakowaniu. Jeśli dostarczono, pudełko mogło zostać otwarte.
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Specifications

Contacts Type And Composition
1 NC + 1 NO + 1 NO
Range Of Product
Telemecanique Safety switches XCS
Insulation
double insulated
Cable Entry
2 entries tapped Pg 11
Clamping Connection Capacity
1 x 0.34...2 x 0.75 mm² with or without cable end
Contact Operation
slow-break, break before make
Type Of Operator
spindle 30 mm
Electrical Connection
terminal
Product Or Component Type
guard switch
Component Name
XCSTR
Material
plastic
Number Of Poles
3
Head Type
turret head rotary axis

Contractual warranty

Warranty
18 months

Complementary

Height
117-117 mm
[Ui] Rated Insulation Voltage
300 VUL 508 || 300 VCSA C22.2 No 14 || 400 V 3)EN/IEC 60947-1
Short-Circuit Protection
6 A cartridge fuse gG (gl)
Positive Opening
with NC contact
Minimum Actuation Speed
0.1 m/s
Positive Opening Minimum Torque
0.45 N.m
Mechanical Durability
1000000 cycles
[Ithe] Conventional Enclosed Thermal Current
6 A
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Material
polyamide PA66 fibre glass impregnated
Lever Material
stainless steel
Contact Code Designation
B300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 || B300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 125 V, Ie = 0.2 A)EN/IEC 60947-5-1 || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1
Tripping Angle
5 °
Width
52 mm
Depth
60 mm
Cable Outer Diameter
7-10 mm
Minimum Torque For Tripping
0.1 N.m
Net Weight
0.155 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-5-1
Maximum Resistance Across Terminals
30 mOhm EN/IEC 60947-5-4
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508

Offer Sustainability

Circularity Profile
ENVEOLI110603EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110606EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CSA || BG || UL
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN/IEC 60204-1 || EN 1088/ISO 14119 || UL 508 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || EN/IEC 60947-5-4 || EN/ISO 12100
Electrical Shock Protection Class
class II EN/IEC 61140
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
50 gn 10-500 Hz)IEC 60068-2-6
Protective Treatment
TH || TC
Ip Degree Of Protection
IP67 conforming to IEC 60529