Schneider Electric

XMLA500N2C11

pressure switch XMLA 500 bar - fixed scale 1 threshold - 1 C/O
XMLA500N2C11
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Oferta z czasem realizacji przez producenta
Wysyłka:1 - 2 Dni robocze
Najlepsza cena:
Wyślij zapytanie o cenę

Additional Information

Part Number
XMLA500N2C11
UNSPSC
39122210

Specifications

Contacts Type And Composition
1 C/O
Pressure Sensor Type
electromechanical pressure sensor
Pressure Actuator
piston
Electrical Connection
1 male connector EN 175301-803-A (ex DIN43650), 4 pins
Range Of Product
Telemecanique Pressure sensors XM
Line Rated Current
3 A, B300, AC-15 (Ue = 120 V)EN/IEC 60947-5-1 || 1.5 A, B300, AC-15 (Ue = 240 V)EN/IEC 60947-5-1 || 0.1 A, R300, DC-13 (Ue = 250 V)EN/IEC 60947-5-1
Pressure Switch Type Of Operation
detection of 1 single threshold
Product Or Component Type
electromechanical pressure sensor
Adjustable Range Of Switching Point On Falling Pressure
10-455 bar
Materials In Contact With Fluid
316L stainless steel || FPM, FKM || PTFE
Local Display
with
Fluid Connection Type
G 1/4 (female) ISO 228
Pressure Sensor Size
500 bar
Controlled Fluid
air 0-160 °C) || corrosive fluid 0-160 °C)
Scale Type
fixed differential
Electrical Circuit Type
control circuit
Enclosure Material
zinc alloy
Adjustable Range Of Switching Point On Rising Pressure
30-500 bar
Maximum Permissible Accidental Pressure
1125 bar
Destruction Pressure
2250 bar
Device Short Name
XMLA

Contractual warranty

Warranty
18 months

Complementary

Repeat Accuracy
2 %
Height
113 mm
Terminal Block Type
4 terminals
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Natural Differential At High Setting
45 bar +/- 10 bar)
Contacts Material
silver contacts
Auxiliary Contacts Operation
snap action
Net Weight
0.78 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Maximum Permissible Pressure - Per Cycle
625 bar
Maximum Operating Rate
60 cyc/mn
[Ui] Rated Insulation Voltage
300 V UL 508 || 500 V EN/IEC 60947-1 || 300 V CSA C22.2 No 14
Setting
external
Mechanical Durability
3000000 cycles
Width
35 mm
Depth
75 mm
Natural Differential At Low Setting
20 bar +/- 6 bar)
Maximum Resistance Across Terminals
25 mOhm IEC 255-7 category 3 || 25 mOhm NF C 93-050 method A

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110914EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA || BV || LROS (Lloyds register of shipping) || CCC || EAC
Ambient Air Temperature For Operation
-25-70 °C
Standards
CSA C22.2 No 14 || EN/IEC 60947-5-1 || CE || UL 508
Vibration Resistance
4 gn 30-500 Hz)IEC 60068-2-6
Shock Resistance
50 gn IEC 60068-2-27
Ip Degree Of Protection
IP65 conforming to EN/IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Protective Treatment
TC standard version
Electrical Shock Protection Class
class I IEC 1140 || class I IEC 536 || class I NF C 20-030
Operating Position
any position

Dokumenty

Data Sheet

Pobierz

Powiązane produkty