- Repeat Accuracy
- 3.5 %
- Pressure Actuator
- diaphragm
- Height
- 106 mm
- Terminal Block Type
- 6 terminals
- Terminals Description Iso N°1
- (3-4)NC || (5-6)NC || (1-2)NC
- Possible Differential Minimum At Low Setting
- 1 bar
- Maximum Operating Rate
- 10 cyc/mn
- Adjustable Range Of Switching Point On Falling Pressure
- 0.3-10.3 bar
- Materials In Contact With Fluid
- chromated zinc alloy || canvas covered nitrile
- Electrical Durability
- 1000000 cycles 1.5 kW 10 cyc/mn 0.4 , 400 V AC 3 phase || 500000 cycles 3 kW 10 cyc/mn 0.4 , 400 V AC 3 phase || 600000 cycles 1.5 kW 10 cyc/mn 0.4 , 230 V AC 3 phase || 700000 cycles 2.2 kW 10 cyc/mn 0.4 , 400 V AC 3 phase
- Net Weight
- 0.43 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-1
- Control Type
- Without
- [Ui] Rated Insulation Voltage
- 500 V EN/IEC 60947-1
- Adjustment Range High Setting
- 1.3-12 bar
- Setting
- knurled knob and nut
- Type Of Decompression Valve
- without
- Mechanical Durability
- 1000000 cycles
- Operating Position
- any position
- Enclosure Material
- PA impregnated with fibreglass
- Possible Differential Minimum At High Setting
- 1.7 bar
- Width
- 57 mm
- Depth
- 98 mm
- Possible Differential Maximum At High Setting
- 8.4 bar
- Destruction Pressure
- 30 bar
- Maximum Resistance Across Terminals
- 25 MOhm IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A