Schneider Electric

XS7D1A1DBM12

Inductive proximity sensors XS, inductive sensor XS7 80x80x26, PBT, Sn40mm, 12...24 VDC, M12
XS7D1A1DBM12
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:

Additional Information

Part Number
XS7D1A1DBM12
UNSPSC
39122230
Tariff Code
8536507000
Country of Origin
ID

Specifications

Electrical Connection
male connector M12, 4 pins
[Us] Rated Supply Voltage
12...24 V DC reverse polarity protection
Discrete Output Function
1 NC
Type Of Output Signal
discrete
Range Of Product
Telemecanique Inductive proximity sensors XS
Sensor Name
XS7
Material
plastic
Size
26 mm
Wiring Technique
2-wire
Ip Degree Of Protection
IP67 double insulation conforming to IEC 60529
Series Name
general purpose
Body Type
fixed
Sensor Type
inductive proximity sensor
Detector Flush Mounting Acceptance
flush mountable
Switching Capacity In Ma
1.5...100 mA DC overload and short-circuit protection
Sensor Design
flat form 80 x 80 x 26
Enclosure Material
PBT
Output Circuit Type
DC

Contractual warranty

Warranty
18 months

Complementary

Height
80 mm
Maximum Delay Response
10 ms
Status Led
output state 1 LED yellow)
Operating Zone
0-32 mm
Maximum Voltage Drop
<4 V closed)
Marking
CE
Maximum Residual Current
0.5 mA open state
Switching Frequency
<= 100 Hz
Differential Travel
1...15% of Sr
Maximum Delay Recovery
10 ms
Maximum Delay First Up
10 ms
Supply Voltage Limits
10-36 V DC
Detection Face
frontal
Width
80 mm
Front Material
PBT
Depth
26 mm

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP071001EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || Ecolab || C-tick || CSA
Ambient Air Temperature For Operation
-25-70 °C
Vibration Resistance
25 gn +/- 2 mm 10-55 Hz)IEC 60068-2-6
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Ambient Air Temperature For Storage
-40-85 °C

Dokumenty

Data Sheet

Pobierz

Powiązane produkty