Photoelectric sensors XU, XU2, thru beam, high gain, Sn 50 m, 12...24 VDC, M12
XU2M18AP20D
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Łącznie 17 części w magazynie od 12 dostawców

Additional Information

Part Number
XU2M18AP20D
UNSPSC
39121528
Tariff Code
8541498000
Country of Origin
FR

Specifications

Electrical Connection
1 male connector M12, 4 pins
Discrete Output Type
PNP
Discrete Output Function
1 NO
Type Of Output Signal
discrete || analogue
Range Of Product
Telemecanique Photoelectric sensors XU
Emission
infrared thru beam
Line Of Sight Type
axial
Sensor Name
XU2
Material
metal
Analogue Output Range
4...20 mA
Wiring Technique
3-wire
Series Name
Application material handling
Detection System
thru beam
Sensor Design
cylindrical M18
Supply Circuit Type
DC
Electronic Sensor Type
photo-electric sensor
[Sn] Nominal Sensing Distance
50-50 m thru beam

Contractual warranty

Warranty
18 months

Complementary

Current Consumption
<= 55 mA no-load
Switching Frequency
<= 30 Hz
Maximum Delay Response
15 ms
Diameter
18 mm
Status Led
1 LED green)supply on || 1 LED yellow)operation
Setting-Up
sensitivity adjustment
Lens Material
PMMA
Maximum Voltage Drop
<1.5 V closed state)
Add On Input
breaking test (transmitter)
Length
95 mm
Net Weight
0.155 kg
Maximum Delay Recovery
15 ms
Maximum Delay First Up
50 ms
Maximum Sensing Distance
70 m
Supply Voltage Limits
10-30 V DC
Switching Capacity In Ma
<= 100 mA overload and short-circuit protection)
Enclosure Material
Nickel Plated Brass
Output Type
solid state
Add On Output
with analogue output
Kit Composition
transmitter + receiver
[Us] Rated Supply Voltage
12...24 V DC reverse polarity protection

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111230EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI111208EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || CE || UL
Vibration Resistance
25 gn +/- 2 mm 10-55 Hz) IEC 60068-2-6
Ambient Air Temperature For Operation
-25-55 °C
Shock Resistance
30 gn 11 ms) IEC 60068-2-27
Ambient Air Temperature For Storage
-40-70 °C
Ip Degree Of Protection
IP67 IEC 60529

Dokumenty

Data Sheet

Pobierz

Powiązane produkty