Schneider Electric
XU2S18PP340WD
Safety thru beam pair photo electric sensors, Preventa Safety detection, security light curtain XU2 S, of body, 750...1200 mm, 12...24 V
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Łącznie 1 część w magazynie od 9 dostawców
Stan produktu:
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
Wyślij zapytanie o cenę
Additional Information
- Part Number
- XU2S18PP340WD
- UNSPSC
- 32151802
- Tariff Code
- 8541498000
- Country of Origin
- FR
Specifications
- Range Of Product
- Telemecanique Safety light curtains XUSL
- Product Or Component Type
- safety thru-beam pair photo-electric sensors
- [Sn] Nominal Sensing Distance
- 8-8 m
- Output Type
- 1 safety outputs OSSD PNP
- Device Short Name
- XU2S
Contractual warranty
- Warranty
- 18 months
Complementary
- Electrical Connection
- 1 male connector M12 4 pins
- Function Available
- built-in muting function || light or dark programmable switching
- Current Consumption
- <= 35 mA no-load
- Switching Frequency
- 500 Hz maximum
- Maximum Delay Response
- 1 ms
- Maximum Delay Recovery
- 1 ms
- Material
- nickel plated brass case || PMMA (polymethyl methacrylate) lenses
- Detection System
- transmitter-receiver system
- Switching Capacity In Ma
- <= 100 mA overload and short-circuit protection)
- Maximum Voltage Drop
- <1.5 V closed)
- Line Of Sight Type
- 90° to case axis
- Marking
- CE
- Net Weight
- 0.155 kg
- Tightening Torque
- 24 N.m fixing nut || 2 N.m connector
- [Us] Rated Supply Voltage
- 12...24 V DC 10...30 V reverse polarity protection
Offer Sustainability
- Circularity Profile
- ENVEOLI111208EN
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP111230EN
- Sustainable Offer Status
- Green Premium product
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environment
- Ambient Air Temperature For Operation
- -25-55 °C
- Ambient Air Temperature For Storage
- -40-70 °C
- Standards
- EN/IEC 61496-2 || EN/IEC 61496-1 || EN/IEC 60825-1
- Safety Reliability Data
- PFH = 5.5E-7 1/h with muting function IEC 61508 || PFH = 4.6E-7 1/h IEC 61508
- Shock Resistance
- 30 gn 3 axes : 3 times EN/IEC 60068-2-27
- Vibration Resistance
- 7 gn 10-55 Hz)EN/IEC 60068-2-6
- Ip Degree Of Protection
- IP67 conforming to EN/IEC 60529
- Safety Level
- can reach PL = c associated with module XPSCM correctly wired EN/ISO 13849-1 || can reach category 2 associated with module XPSCM correctly wired EN/ISO 13849-1 || type 2 IEC 61496-1-2