Photoelectric sensors XU, XUK, receiver, Sn 30 m, 24...240VAC/DC, cable 2 m
XUK2ARCNL2R
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Łącznie 22 części w magazynie od 16 dostawców

Additional Information

Part Number
XUK2ARCNL2R
UNSPSC
39121528
Tariff Code
8541498000
Country of Origin
ID

Specifications

Electrical Connection
cable
Discrete Output Function
1 NC + 1 NO
Type Of Output Signal
discrete
Range Of Product
Telemecanique Photoelectric sensors XU
Cable Length
2 m
Emission
infrared thru beam
Sensor Name
XUK
Material
plastic
Wiring Technique
5-wire
Series Name
general purpose single mode
Detection System
thru beam
Sensor Design
compact 50 x 50
Supply Circuit Type
AC/DC
Electronic Sensor Type
photo-electric sensor receiver
[Sn] Nominal Sensing Distance
30-30 m thru beam need a transmitter XUK2ARCNL2T

Contractual warranty

Warranty
18 months

Complementary

Height
50 mm
Switching Frequency
<= 20 Hz
Maximum Delay Response
25 ms
Status Led
1 LED yellow)output state
Setting-Up
without sensitivity adjustment
Lens Material
PMMA
Maximum Voltage Drop
<1.5 V closed state)
Net Weight
0.07 kg
Maximum Delay Recovery
25 ms
Electrical Durability
500000 cycles 1 60 cyc/mn 250 V
Maximum Delay First Up
60 ms
Maximum Sensing Distance
45 m thru beam
Supply Voltage Limits
20-264 V AC/DC
Switching Capacity In Ma
3 A cos φ = 1 for 0.5 million cycles at 1 operating cycle per second at 250 V)
Wire Insulation Material
PVC
Enclosure Material
PBT
Width
18 mm
Output Type
relay
Depth
50 mm
Maximum Power Consumption In W
2 W AC
Add On Output
without
[Us] Rated Supply Voltage
24...240 V AC/DC

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111232EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI111207EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CE || CSA || UL
Ambient Air Temperature For Operation
-25-55 °C
Vibration Resistance
7 gn +/- 1.5 mm 10-55 Hz) IEC 60068-2-6
Shock Resistance
30 gn 11 ms) IEC 60068-2-27
Ambient Air Temperature For Storage
-40-70 °C
Ip Degree Of Protection
IP65 double insulation IEC 60529