Schneider Electric
XUM8APCNL03M12
Photoelectric sensors XU, XUM, BGS, Sn 0.3 m, 12...24 VDC, M12, cable 0.3 m
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Stan produktu:
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
Wyślij zapytanie o cenę
Additional Information
- Part Number
- XUM8APCNL03M12
- UNSPSC
- 39121528
- Country of Origin
- CN
Specifications
- Electrical Connection
- remote male connector M12, 4 pins
- Discrete Output Type
- PNP
- Discrete Output Function
- 1 NO or 1 NC programmable
- Type Of Output Signal
- discrete
- Range Of Product
- Telemecanique Photoelectric sensors XU
- Cable Length
- 0.3 m
- Emission
- red diffuse with background suppression
- Sensor Name
- XUM
- Material
- plastic
- Wiring Technique
- 3-wire
- Series Name
- general purpose single mode
- Detection System
- diffuse with background suppression
- Sensor Design
- miniature
- Supply Circuit Type
- DC
- Electronic Sensor Type
- photo-electric sensor
- [Sn] Nominal Sensing Distance
- 0.3-0.3 m diffuse with background suppression
Contractual warranty
- Warranty
- 18 months
Complementary
- Current Consumption
- <= 20 mA no-load
- Height
- 33 mm
- Maximum Delay Response
- 1 ms
- Status Led
- 1 LED green)instability || 1 LED orange)output state
- Setting-Up
- sensitivity adjustment by potentiometer
- Lens Material
- PC
- Maximum Voltage Drop
- <2 V closed state)
- Length
- 11 mm
- Net Weight
- 0.02 kg
- Maximum Delay First Up
- 100 ms
- Maximum Sensing Distance
- 0.3 m diffuse with background suppression
- Supply Voltage Limits
- 10-30 V DC
- Switching Capacity In Ma
- <= 100 mA overload and short-circuit protection)
- Wire Insulation Material
- PVC
- Enclosure Material
- PBT
- Width
- 11 mm
- Output Type
- solid state
- Depth
- 20 mm
- [Us] Rated Supply Voltage
- 12...24 V DC reverse polarity protection
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CE || cURus
- Vibration Resistance
- 20 gn +/- 1.5 mm 10-500 Hz) IEC 60068-2-6
- Ambient Air Temperature For Operation
- -25-55 °C
- Shock Resistance
- 50 gn 11 ms) IEC 60068-2-27
- Ambient Air Temperature For Storage
- -30-70 °C
- Ip Degree Of Protection
- IP67 IEC 60529
- Immunity To Ambient Light
- 3000 lux natural light || 3000 lux incandescent light