Schneider Electric

XY2CE1A190H7

Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, cable 300 VAC 10amp XY2CE+options
XY2CE1A190H7
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
Wyślij zapytanie o cenę

Additional Information

Part Number
XY2CE1A190H7
UNSPSC
39122213
Tariff Code
8536509055
Country of Origin
MA

Specifications

Range Of Product
Telemecanique Emergency stop rope pull switches XY2C
Overvoltage Category
class I EN/IEC 61140 || class I NF C 20-030
Product Or Component Type
latching emergency stop rope pull switch
Device Short Name
XY2CE

Contractual warranty

Warranty
18 months

Complementary

Connections - Terminals
screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Reset
by flush push-button
Contacts Type And Composition
1 NC + 1 NO
Terminals Description Iso N°1
(21-22)NC || (13-14)NO
[Ui] Rated Insulation Voltage
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60269
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operation
slow-break
Distance Between Cable Supports
5-5 m
Mechanical Durability
60000 cycles
Positive Opening
with EN/IEC 60947-5-1
Cable Entry Number
3 plain hole Pg 13.5 or ISO M20 cable gland
Compatibility Code
XY2CE
Body Material
zamak
[Ithe] Conventional Enclosed Thermal Current
10 A
Trigger Cable Anchor Point
RH side
Safety Reliability Data
B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Marking
CE
Cover Material
stainless steel
Local Signalling
without pilot light
Net Weight
1.45 kg
Tightening Torque
0.8-1.2 N.m
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111159EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN/IEC 60947-5-5 || machinery directive 2006/42/EC || EN/ISO 13850 || CSA C22.2 No 14 || UL 508 || EN/IEC 60947-5-1 || work equipment directive 2009/104/EC || EN/IEC 60204-1
Product Certifications
UL category NISD emergency stop devices || CSA || CCC
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
10 gn 10-300 Hz)EN/IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP66 IEC 60529

Dokumenty

Data Sheet

Pobierz

Powiązane produkty