Wago
221-415
COMPACT splicing connector; 5-conductor; with operating levers; 12 AWG; transparent housing
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
€0.66
1
Metody płatności:
Łącznie 513 987 części w magazynie od 36 dostawców
Stan produktu:
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
€0.37
Additional Information
- Part Number
- 221-415
- UPC
- 4055143234658
- Tariff Code
- 85369010000
- ETIM
- Group Code : EG000047
- Group Description : Installation, isolation and connection material
- Class Description : Screw less terminal
- Class Code : EC000446
- Version : 7
Ratings Per Iec/En
- Ratings per
- EN 60664
- Nominal voltage (II/2)
- 450 V
- Rated surge voltage (II/2)
- 4 kV
- Rated current
- 32 A
- Legend (ratings)
- (II / 2) ≙ Overvoltage category II / Pollution degree 2
Environmental Requirements
- Continuous operating temperature
- 105 °C
- Temperature marking per EN 60998
- T85
Physical Data
- Width
- 30 mm / 1.181 inches
- Height
- 8.6 mm / 0.327 inches
- Depth
- 18.8 mm / 0.732 inches
Material Data
- Note (material data)
- <a href="https://www.wago.com/us/material-specifications" href="_blank">Information on material specifications can be found here</a>
- Color
- Transparent
- Insulation material
- Polycarbonate (PC)
- Flammability class per UL94
- V2
- Fire load
- 0.089 MJ
- Actuator color
- Orange
- Weight
- 4.048 g
Specifications
- Product Group Code
- 0007
Commercial Data
- Packaging type
- Box
- Country of origin
- DE
- GTIN
- 4055143234658
- Customs tariff number
- 85369010000
Notes
- Safety information
- In grounded power lines
Connection 1
- Connection technology
- CAGE CLAMP®
- Actuation type
- Lever
- Connectable conductor materials
- Copper
- Nominal cross-section
- 4 mm² / 12 AWG
- Solid conductor
- 0.2 … 4 mm² / 24 … 12 AWG
- Stranded conductor
- 0.2 … 4 mm² / 24 … 12 AWG
- Fine-stranded conductor
- 0.14 … 4 mm² / 24 … 12 AWG
- Strip length
- 11 mm / 0.43 inches
- Wiring direction
- Side-entry wiring
Ratings Per Ul 1059
- Approvals per
- UL 486C
- Rated voltage UL (Use Group C)
- 600 V
- Rated current UL (Use Group C)
- 20 A