Wago

750-663/000-003

Intrinsically safe 4-channel digital input; 24 VDC; PROFIsafe V2.0 iPar
750-663/000-003
750-663/000-003
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Łącznie 231 części w magazynie od 13 dostawców

Additional Information

Part Number
750-663/000-003
UPC
4050821531432
Tariff Code
85389099990
ETIM
Group Code : EG000024
Group Description : PLC's
Class Description : Fieldbus, decentr. periphery - digital I/O module
Class Code : EC001599
Version : 7

Environmental Requirements

Ambient temperature (operation)
0 … +55 °C
Ambient temperature (storage)
-25 … +85 °C
Protection type
IP20
Pollution degree
2 per IEC 61131-2
Operating altitude
0 … 2000 m / 0 … 6562 ft
Mounting position
Horizontal (standing/lying); vertical
Relative humidity (without condensation)
95 %
Vibration resistance
4g per IEC 60068-2-6
Shock resistance
15g per IEC 60068-2-27
EMC immunity to interference
Per EN 61000-6-2, marine applications
EMC emission of interference
Per EN 61000-6-3, marine applications
Exposure to pollutants
Per IEC 60068-2-42 and IEC 60068-2-43
Permissible H2S contaminant concentration at a relative humidity 75 %
10 ppm
Permissible SO2 contaminant concentration at a relative humidity 75 %
25 ppm

Connection Data

Connection technology: inputs/outputs
8 x CAGE CLAMP®
Connection type 1
Inputs/outputs
Solid conductor
0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor
0.08 … 2.5 mm² / 28 … 14 AWG
Strip length
8 … 9 mm / 0.31 … 0.35 inches
Connection requirement (permissible cable length)
100 m

Physical Data

Width
24 mm / 0.945 inches
Height
100 mm / 3.937 inches
Depth
67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail
60.6 mm / 2.386 inches

Material Data

Housing material
Polycarbonate; polyamide 6.6
Fire load
2.021 MJ
Weight
91.988 g
Conformity marking
CE

Functional Safety

Achievable risk reduction
SIL 3 per IEC 61508; SIL 3 per IEC 61511; SIL 3 per IEC 62061; Cat. 4, PL e per EN ISO 13849
Safety standards
IEC 61508; IEC 62061; EN ISO 13849; IEC 61511

Technical Data

Number of digital inputs
4
Total number of channels (module)
4
Signal type
Digital
Signal type (voltage)
24 VDC
Sensor connection
4 x (Fail-safe input with test pulse)
Input characteristic
Clock sensitive || Type 1
Input filter (digital)
0.5 ms || 1 ms || 2 ms || 3 ms || 5 ms || 10 ms || 20 ms || 50 ms || 100 ms || 200 ms || 0 ms
Input filter
0 … 200 ms (parameterizable in steps)
Input filter: parametrizable (channel by channel)
Yes
Input current per channel for signal (1) typ.
3 mA
Output current per channel
0.05 A
Short-circuit current
≤ 25 mA
Signal frequency (max.)
50 Hz
Intrinsic safety Ex i
Yes
Configuration options
PROFIsafe address adjustable via DIP switch or engineering software
Supply voltage (system)
5 VDC; via data contacts
Current consumption (5 V system supply)
145 mA
Supply voltage (field)
24 VDC; (Ex i power supply: UO = max. 27.3 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)
Current consumption, field supply (module with no external load)
20 mA
Isolation
300 VAC system/field
Indicators
LED (A-D) green/red: Status/Error I1 … I4; LED (E) red: Group error; LED (F-H) green/red: Diagnostics
Number of incoming power jumper contacts
2
Number of outgoing power jumper contacts
2
Current carrying capacity (power jumper contacts)
1 A
Marking
ATEX/IECEx: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I

Mechanical Data

Mounting type
DIN-35 rail

Specifications

Product Group Code
0015

Commercial Data

Packaging type
Box
Country of origin
DE
GTIN
4050821531432
Customs tariff number
85389099990

Explosion Protection

Ex standard
EN IEC 60079-0, -7, -11
Safety-relevant data (circuit)
Uo = 27.3 V; Io = 23 mA; Po = 157 mW; linear characteristic curve
Reactances Ex ia IIC
Lo = 61 mH; Co = 64 nF
Reactances Ex ia IIB
Lo = 100 mH; Co = 552 nF
Reactances Ex ia IIA
Lo = 100 mH; Co = 2.28 µF
Reactances Ex ia I
Lo = 100 mH; Co = 2.95 µF
Reactances (note)
Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)

Powiązane produkty