Offer Description

The MS116-16 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 16.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 16 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.MS116-16 Manual Motor Starter 10 16 A ABB 1SAM250000R1011

Product Description

The MS116-16 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 16.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 16 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.

Product Details

Brand
ABB
Country of Origin
DE
Part Number
1SAM250000R1011
Tariff Code
85362010
EAN
4013614320347
UNSPSC
39121521
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Motor protection circuit-breaker
Class Code : EC000074
Version : 7
$128.09
excl. tax
Free Shipping!

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 13-07-2025
Warranty:
12 months
Estimated Delivery:
18-23 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Dimensions

Product Net Width
45 mm
Product Net Height
90 mm
Product Net Depth / Length
85.6 mm
Product Net Weight
0.265 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)
(230 V AC) 16 kA(400 V AC) 16 kA(440 V AC) 6 kA(500 V AC) 4 kA(690 V AC) 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(230 V AC) 16 kA(400 V AC) 16 kA(440 V AC) 15 kA(500 V AC) 10 kA(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)
240 A
Setting Range
10 ... 16 A
Rated Operational Power AC-3 (Pe)
(400 V) Three Phase 7.5 kW
Rated Operational Power AC-3e (Pe)
(400 V) Three Phase 7.5 kW
Rated Operational Voltage
Main Circuit 690 V AC
Rated Operational Current (Ie)
16 A
Rated Operational Current AC-3 (Ie)
16 A
Rated Operational Current AC-3e (Ie)
16 A
Rated Frequency (f)
Main Circuit 50 HzMain Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
at Rated Operating Conditions per Pole 1.1 ... 2.8 W
Number of Poles
3
Conventional Free-air Thermal Current (Ith)
Main Circuit 16 A
Degree of Protection
Housing IP20Main Circuit Terminals IP10
Pollution Degree
3
Electrical Durability
100000 cycle
Mechanical Durability
100000 cycle
Terminal Type
Screw Terminals
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²Flexible 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²
Tightening Torque
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length
Main Circuit 9 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
any1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance
Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
Actuator Type
Rotary Handle
Contact Position Indication
ON / OFF
Standards
IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1

Classifications

Object Classification Code
F
ETIM 4
EC000074 - Motor protective circuit-breaker
ETIM 5
EC000074 - Motor protective circuit-breaker
EClass
V11.0 : 27370401
IDEA Granular Category Code (IGCC)
4731 >> Manual Starters
E-Number (Finland)
3706011
E-Number (Sweden)
3111950

Environmental

Ambient Air Temperature
Around the Enclosure 0 ... +40 °COperation -25 ... +70 °COperation Compensated -25 ... +55 °CStorage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6
5g / 3 ... 150 Hz
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Technical UL/CSA

Short-Circuit Current Rating (SCCR)
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Horsepower Rating UL/CSA
(200 V AC) Three Phase 3 Hp(208 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 5 Hp(440 ... 480 V AC) Three Phase 10 Hp(550 ... 600 V AC) Three Phase 10 Hp
Full Load Amps Motor Use
(200 V AC) Three Phase 11 A(208 V AC) Three Phase 10.6 A(220 ... 240 V AC) Three Phase 15.2 A(440 ... 480 V AC) Three Phase 14 A(550 ... 600 V AC) Three Phase 11 A
Locked Rotor Amps
(200 V AC) Three Phase 73.6 A(208 V AC) Three Phase 71 A(220 ... 240 V AC) Three Phase 92 A(440 ... 480 V AC) Three Phase 81 A(550 ... 600 V AC) Three Phase 64.8 A
General Use Rating UL/CSA
(600 V AC) 16 A
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 16-8 AWGStranded 1/2x 16-8 AWG
Tightening Torque UL/CSA
Main Circuit 10 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85362010

Documents

Data Sheet

Datasheet for ABB 1SAM250000R1011, including specifications and features.

Download Data Sheet