Need more information?

Call us at:+48 17 778 34 19

ABB 1SFL637001R6911AF750-30-11 48-130V 50/60Hz / 48-130V DC Contactor

1 / 2
1SFL637001R6911 ABB, Other
Reference Image - Not actual item!
1SFL637001R6911 ABB, Other
1SFL637001R6911 ABB, Other
1SFL637001R6911 ABB, Other

Offer Description

The AF750-30-11-69 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 400 kW / 400 V AC (AC-3) or 600 hp / 480 V UL and switching power circuits up to 1050 A (AC-1) or 900 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.AF750-30-11 48-130V 50/60Hz / 48-130V DC Contactor ABB 1SFL637001R6911

Product Description

The AF750-30-11-69 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 400 kW / 400 V AC (AC-3) or 600 hp / 480 V UL and switching power circuits up to 1050 A (AC-1) or 900 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Product Details

Brand
ABB
Country of Origin
SE
Part Number
1SFL637001R6911
Tariff Code
85364900
EAN
7320500220405
UPC
73205002204050
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7
$2,920.27
excl. tax
Free Shipping!

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 18-07-2025
Warranty:
12 months
Estimated Delivery:
25-30 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Dimensions

Product Net Width
210 mm
Product Net Depth / Length
242 mm
Product Net Height
283 mm
Product Net Weight
13.6 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 1000 A(1000 V) 55 °C 875 A(1000 V) 70 °C 720 A(690 V) 40 °C 1050 A(690 V) 55 °C 875 A(690 V) 70 °C 720 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 750 A(440 V) 55 °C 750 A(500 V) 55 °C 750 A(690 V) 55 °C 650 A(1000 V) 55 °C 300 A(380 / 400 V) 55 °C 750 A(220 / 230 / 240 V) 55 °C 750
Rated Operational Power AC-3 (Pe)
(415 V) 425 kW(440 V) 450 kW(500 V) 520 kW(690 V) 600 kW(1000 V) 400 kW(380 / 400 V) 400 kW(220 / 230 / 240 V) 220 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 1000 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 1050 A(110 V) 2 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 40 °C 1050 A(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 1050 A(110 V) 2 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 40 °C 1050 A(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 1050 A(110 V) 2 Poles in Series, 40 °C 1050 A(220 V) 3 Poles in Series, 40 °C 1050 A(600 V) 3 Poles in Series, 40 °C 1050 A(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Mechanical Durability
3 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V60 Hz 48 ... 130 VDC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 1100 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 1100 V·APull-in at Max. Rated Control Circuit Voltage DC 1020 V·A
Operate Time
Between Coil De-energization and NC Contact Closing 50 ... 70 msBetween Coil De-energization and NO Contact Opening 53 ... 73 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 52 mm²Rigid Al-Cable 3x185 mm²Rigid Cu-Cable 300 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 1 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type
Main Circuit: Bars

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Norway)
4115299
E-Number (Sweden)
3228364

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Technical UL/CSA

NEMA Size
7
Horsepower Rating NEMA
(230 V AC) Three Phase 300 Hp(460 V AC) Three Phase 600 Hp(575 V AC) Three Phase 600 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 900 A(600 V AC) 900 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 250 hp(208 V AC) Three Phase 250 hp(220 ... 240 V AC) Three Phase 300 hp(440 ... 480 V AC) Three Phase 600 hp(550 ... 600 V AC) Three Phase 700 hp

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900

Related products

2CDS282001R0408 ABB, Power Supply
2CDS282001R0408
ABB
S202P-Z8 Miniature Circuit Breaker - 2P - Z - 8 A
1SNK155102R0000 ABB, Other
1SNK155102R0000
ABB
MC612PA Terminal Block Markers pre-printed : 901->1000 Vertical
1SNK522010R0000 ABB, Other
1SNK522010R0000
ABB
ZS70 Screw Clamp Terminal Block - Feed-through - Grey
1SNK905305R0000 ABB, Other
1SNK905305R0000
ABB
JB5-5 Jumper Bar - Orange
CB5.10 ABB, Other
CB5.10
ABB
A AUX BLK,1NO,IMPULSE
PSE72-600-70 ABB, Drives
PSE72-600-70
ABB
SOFTSTARTER
2CDS283001R0557 ABB, Power Supply
2CDS283001R0557
ABB
S203P-K40 Miniature Circuit Breaker - 3P - K - 40 A
1SNA295381R2600 ABB, Other
1SNA295381R2600
ABB
BNS.D5 Component Plugs Beige
1SNK146251R0000 ABB, Other
1SNK146251R0000
ABB
MC512PA Terminal Block Markers pre-printed : Y (x100) Horizontal
1SNK900618R0000 ABB, Other
1SNK900618R0000
ABB
PL5 Protecting Cover - Transparent