1 / 1
thumbnail

Beschreibung

Aktiv Reif
Country of Origin
MX
Part Number
9012GMW2
Tariff Code
9032200000
EAN
39122210
UPC
785901048848
UNSPSC
39122210
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign-Up
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Fordern Sie ein Angebot an und wir senden Ihnen Informationen zu Verfügbarkeit und Preis.

Specifications

Pressure Sensor Type
electromechanical pressure switch
Pressure Sensor Size
2900 psi
Controlled Fluid
hydraulic oil -15-250 °F) || selected corrosive gases || air || non-corrosive gas
Range Of Product
9012G
Scale Type
fixed
Maximum Pressure
15000 psi
Pressure Switch Type Of Operation
regulates two separate pressure thresholds
Contacts Type And Composition
2(NC-NO), 2 SPDT-DB, Form Z, snap action, silver nickel contacts
Local Display
without
Pressure Sensor Name
9012G
Fluid Connection Type
0.25 inch 18 NPTF UL 508

Contractual warranty

Warranty
18 months

Complementary

Repeat Accuracy
4 %
Height
6.37 in
Pressure Actuator
piston
Maximum Operating Rate
120 cyc/mn
Terminal Block Type
8 screw terminals
Short-Circuit Protection
10 A cartridge overload and short-circuit protection gL
Approx Fix Differential At Mid Range
140 psi stage 1 +/- 30 psig +/- 2.5 % full scale || 210 psi stage 2 +/- 52 psig
Setting
internal
Mechanical Durability
3000000 cycles
Line Rated Current
3 A 240 V AC A600 NEMA rating designation || 6 A 120 V AC A600 NEMA rating designation || 0.27 A 250 V DC R300 NEMA rating designation || 0.22 A 125 V DC R300 NEMA rating designation
Range On Decreasing Pressure
90-2900 psi
Cable Entry
0.5 inch NPT conduit entrance
Operating Position
any position
Electrical Connection
screw-clamp terminals, AWG 22...AWG 12
Electrical Circuit Type
control circuit
Enclosure Material
die cast aluminium alloy 380
Width
3.5 in
Depth
2.63 in
Materials In Contact With Fluid
440 stainless steel || Viton fluorocarbon
Net Weight
2.5 lb(US)
Local Signalling
without

Offer Sustainability

Circularity Profile
ENVEOLI111210EN
Environmental Disclosure
ENVPEP111211EN
Eu Rohs Directive
Not applicable, out of EU RoHS legal scope
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CE || UL listed file E12158 CCN NKPZ and CCN NTHT
Ambient Air Temperature For Operation
-10-185 °F
Standards
CSA C22.2 No 14 || CE
Nema Degree Of Protection
NEMA 4/4X/13 UL 50
Shock Resistance
50 gn IEC 58-2-27
Vibration Resistance
2 gn 40-150 Hz)IEC 68-2-6

Dokumente

Data Sheet

Herunterladen