Schneider Electric
9016GVG1J09E
1 / 1
Opis
Końcówka Serii
This product is part of the NEMA Pressure Switches range, an offer of electromechanical vacuum switches. This electromechanical vacuum switch has 2 normally closed, snap action, DPST-DB (double pole double throw, double break), form YY contacts and maximum pressure of 150psi. The vacuum switch with an approximate differential of 5inHg to 10inHg. Vacuum switch has a cut range of 5InHg to 25InHg and a cut in range of 0InHg to 20InHg. Switch is set to 3InHg to 8InHg. It is furnished with screw clamp terminals for electrical connection and 0.25inch 18 NPSF for fluid connection. This vacuum switch has a diaphragm actuator which can be operated from any position and adjustable scale for internal settings. Offers mechanical durability of 300 operating cycles. The enclosure is made of stamped metal. It is available in size of 4.58inch (W) x 4.37inch (D) x 7.13inch (H) and weighs 4.6lb. It is suitable for pressure controlling or monitoring of water pumps, compressors, agricultural/irrigation water systems, molding presses, injection molders, grinding machines, machining centers, complex and special machines. It is a NEMA 1 rated product. This product is certified by CSA and UL. Meets UL 508 standards. Electromechanical vacuum switch is designed as a companion to the 9036GG float switches in common use on vacuum heating pumps. Electromechanical vacuum switch is designed as a companion to the 9036GG float switches in common use on vacuum heating pumps.- Country of Origin
- MX
- Part Number
- 9016GVG1J09E
- Tariff Code
- 9032200000
- EAN
- 39122228
- UPC
- 785901852193
- UNSPSC
- 39122228
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Specifications
- Range Of Product
- 9016GVG
- Product Or Component Type
- electromechanical vacuum switch
- Electrical Circuit Type
- power circuit
- Device Application
- power circuit application
- Device Short Name
- 9016GVG
Contractual warranty
- Warranty
- 18 months
Complementary
- Vacuum Sensor Size
- 25 inHg
- Height
- 7.13 in
- Pressure Actuator
- diaphragm nitrile (Buna-N)
- Terminal Block Type
- 8 screw terminals
- Short-Circuit Protection
- 20 A cartridge fuse gG
- Repeat Accuracy
- 2.5 %
- Maximum Pressure
- 100 psi
- Factory Modification
- 3-way lever
- Electrical Connection
- screw-clamp terminals AWG 22...AWG 12
- Contacts Type And Composition
- 2 NC, DPST-DB, Form YY, snap action, silver cadmium contacts
- Materials In Contact With Fluid
- nitrile (Buna-N) || 3M Scotch-Grip 847 rubber and gasket adhesive || zinc plated steel
- Local Display
- without
- Net Weight
- 4.6 lb(US)
- Maximum Permissible Pressure - Per Cycle
- 100 psi
- Fluid Connection Type
- 0.25 inch 18 NPSF UL 508
- Cable Entry Number
- 3 knock-outs for 1/2" NPT conduit
- Vacuum Switch Type Of Operation
- regulation between two thresholds
- Maximum Operating Rate
- 100 cyc/mn
- Controlled Fluid
- air -40-250 °F) || water -40-250 °F) || hydraulic oil -40-250 °F) || gas -40-250 °F)
- Cut-In Range
- 0-20 inHg
- Approx Adjustable Differential At Mid Range
- 5-10 inHg
- Setting
- internal
- Value Of Setting
- 3...8 inHg
- Scale Type
- adjustable
- Mechanical Durability
- 300 cycles
- Operating Position
- any position
- Enclosure Material
- stamped metal
- Cut Out Range
- 5-25 inHg
- Width
- 4.58 in
- Depth
- 4.37 in
- Cover Material
- polypropylene, noryl thermoplastic resin or equivalent
- Motor Power Kw
- 1.5 kW 2 hp)115 V AC, 1 phase || 2.2 kW 3 hp)115 V AC, 3 phase || 2.2 kW 3 hp)230 V AC, 1 phase || 3.75 kW 5 hp)230 V AC, 3 phase || 3.7 kW 5 hp)460 V AC, 1 phase || 3.7 kW 5 hp)460 V AC, 3 phase || 3.7 kW 5 hp)575 V AC, 1 phase || 3.7 kW 5 hp)575 V AC, 3 phase || 0.75 kW 1 hp)115 V DC, 3 phase || 0.75 kW 1 hp)230 V DC
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP111211EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Circularity Profile
- ENVEOLI111210EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- UL listed file E12158 CCN NKPZ || CSA file LR25490
- Ambient Air Temperature For Operation
- 10-185 °F
- Standards
- UL 508
- Ambient Air Temperature For Storage
- 10-185 °F
- Nema Degree Of Protection
- NEMA 1 UL 698
- Protective Treatment
- none
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne