This product is part of the NEMA Pressure Switches range, an offer of electromechanical vacuum switches. This electromechanical vacuum switch has 2 normally closed, snap action, DPST-DB (double pole double throw, double break), form YY contacts and maximum pressure of 150psi. The vacuum switch with an approximate differential of 5inHg to 10inHg. Vacuum switch has a cut range of 5InHg to 25InHg and a cut in range of 0InHg to 20InHg. Switch is set to 3InHg to 8InHg. It is furnished with screw clamp terminals for electrical connection and 0.25inch 18 NPSF for fluid connection. This vacuum switch has a diaphragm actuator which can be operated from any position and adjustable scale for internal settings. Offers mechanical durability of 300 operating cycles. The enclosure is made of stamped metal. It is available in size of 4.58inch (W) x 4.37inch (D) x 7.13inch (H) and weighs 4.6lb. It is suitable for pressure controlling or monitoring of water pumps, compressors, agricultural/irrigation water systems, molding presses, injection molders, grinding machines, machining centers, complex and special machines. It is a NEMA 1 rated product. This product is certified by CSA and UL. Meets UL 508 standards. Electromechanical vacuum switch is designed as a companion to the 9036GG float switches in common use on vacuum heating pumps. Electromechanical vacuum switch is designed as a companion to the 9036GG float switches in common use on vacuum heating pumps.
Country of Origin
MX
Part Number
9016GVG1J09E
Tariff Code
9032200000
EAN
39122228
UPC
785901852193
UNSPSC
39122228
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Poproś o wycenę, a prześlemy Ci informacje o dostępności i cenie.

Specifications

Range Of Product
9016GVG
Product Or Component Type
electromechanical vacuum switch
Electrical Circuit Type
power circuit
Device Application
power circuit application
Device Short Name
9016GVG

Contractual warranty

Warranty
18 months

Complementary

Vacuum Sensor Size
25 inHg
Height
7.13 in
Pressure Actuator
diaphragm nitrile (Buna-N)
Terminal Block Type
8 screw terminals
Short-Circuit Protection
20 A cartridge fuse gG
Repeat Accuracy
2.5 %
Maximum Pressure
100 psi
Factory Modification
3-way lever
Electrical Connection
screw-clamp terminals AWG 22...AWG 12
Contacts Type And Composition
2 NC, DPST-DB, Form YY, snap action, silver cadmium contacts
Materials In Contact With Fluid
nitrile (Buna-N) || 3M Scotch-Grip 847 rubber and gasket adhesive || zinc plated steel
Local Display
without
Net Weight
4.6 lb(US)
Maximum Permissible Pressure - Per Cycle
100 psi
Fluid Connection Type
0.25 inch 18 NPSF UL 508
Cable Entry Number
3 knock-outs for 1/2" NPT conduit
Vacuum Switch Type Of Operation
regulation between two thresholds
Maximum Operating Rate
100 cyc/mn
Controlled Fluid
air -40-250 °F) || water -40-250 °F) || hydraulic oil -40-250 °F) || gas -40-250 °F)
Cut-In Range
0-20 inHg
Approx Adjustable Differential At Mid Range
5-10 inHg
Setting
internal
Value Of Setting
3...8 inHg
Scale Type
adjustable
Mechanical Durability
300 cycles
Operating Position
any position
Enclosure Material
stamped metal
Cut Out Range
5-25 inHg
Width
4.58 in
Depth
4.37 in
Cover Material
polypropylene, noryl thermoplastic resin or equivalent
Motor Power Kw
1.5 kW 2 hp)115 V AC, 1 phase || 2.2 kW 3 hp)115 V AC, 3 phase || 2.2 kW 3 hp)230 V AC, 1 phase || 3.75 kW 5 hp)230 V AC, 3 phase || 3.7 kW 5 hp)460 V AC, 1 phase || 3.7 kW 5 hp)460 V AC, 3 phase || 3.7 kW 5 hp)575 V AC, 1 phase || 3.7 kW 5 hp)575 V AC, 3 phase || 0.75 kW 1 hp)115 V DC, 3 phase || 0.75 kW 1 hp)230 V DC

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111211EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI111210EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL listed file E12158 CCN NKPZ || CSA file LR25490
Ambient Air Temperature For Operation
10-185 °F
Standards
UL 508
Ambient Air Temperature For Storage
10-185 °F
Nema Degree Of Protection
NEMA 1 UL 698
Protective Treatment
none