1 / 1
thumbnail

Opis

Końcówka Serii
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 0.25kW@400V. It provides full protection to motors with a rated current Ir 0.35-1.4A (Ir adjustable), overload tripping class 20, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 48V AC / 48-72V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Country of Origin
FR
Part Number
LUCD1XES
Tariff Code
85363010
EAN
3389110364866
UNSPSC
43201542
Metody płatności:
Najlepsza oferta od:
DEZaufany dostawca Automa.Net
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 08-11-2024
Gwarancja:
12 miesięcy
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Nowy, Rynek wtórny
Nowy, Rynek wtórny - Nowy, nieużywany, nieuszkodzony przedmiot bez gwarancji producenta. Przedmiot może być dostarczony bez oryginalnego opakowania lub w zastępczym opakowaniu. Jeśli dostarczono, pudełko mogło zostać otwarte.
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Environment

Ambient Air Temperature For Operation
-25-70 °C
Resistance To Radiated Fields
10 V/m 3 IEC 61000-4-3
Non-Dissipating Shock Wave
1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
Shock Resistance
10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Vibration Resistance
2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Immunity To Microbreaks
3 ms
Immunity To Voltage Dips
70 % / 500 ms IEC 61000-4-11
Ip Degree Of Protection
IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
Ambient Air Temperature For Storage
-40-85 °C
Protective Treatment
TH IEC 60068
Resistance To Electrostatic Discharge
8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
Operating Altitude
6561.68 ft (2000 m)
Fire Resistance
960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
Immunity To Radioelectric Fields
10 V IEC 61000-4-6
Resistance To Fast Transients
2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP080204EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI100414
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free plastic parts product

Complementary

Product Certifications
CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Height
66 mm
Reset
manual reset
Fixing Mode
plug-in front face)
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947-6-2
Standards
EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
Typical Current Consumption
280 mA 48 V AC I maximum while closing with LUB12 || 280 mA 48 V AC I maximum while closing with LUB32 || 280 mA 48 V AC I maximum while closing with LUB38 || 280 mA 48...72 V DC I maximum while closing with LUB12 || 280 mA 48...72 V DC I maximum while closing with LUB32 || 280 mA 48...72 V DC I maximum while closing with LUB38 || 35 mA 48 V AC I rms sealed with LUB12 || 45 mA 48 V AC I rms sealed with LUB32 || 45 mA 48 V AC I rms sealed with LUB38 || 35 mA 48...72 V DC I rms sealed with LUB12 || 45 mA 48...72 V DC I rms sealed with LUB32 || 45 mA 48...72 V DC I rms sealed with LUB38
[Ui] Rated Insulation Voltage
690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Compatibility Code
LUCD
Control Circuit Voltage Limits
38.5...72 V AC 48 V in operation || 38.5...93 V DC 48...72 V in operation || 29 V AC 48 V drop-out || 29 V DC 48...72 V drop-out
Operating Time
35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 60 ms closing with LUB12 control circuit || 60 ms closing with LUB32 control circuit || 60 ms closing with LUB38 control circuit
Width
45 mm
Safe Separation Of Circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Depth
60 mm
Heat Dissipation
2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38

Specifications

[Uc] Control Circuit Voltage
48 V AC || 48...72 V DC
[Ue] Rated Operational Voltage
690 V AC
Range Of Product
TeSys Ultra
Phase Failure Sensitivity
yes
Thermal Protection Adjustment Range
0.35-1.4 A
Product Or Component Type
advanced control unit
Product Name
TeSys Ultra
Thermal Overload Class
class 20 40-60 Hz -25-70 °C IEC 60947-6-2 || class 20 40-60 Hz -25-70 °C UL 508
Motor Power Kw
0.25 kW 400...440 V AC 50/60 Hz
Range
TeSys
Utilisation Category
AC-41 || AC-44 || AC-43
Function Available
manual reset || protection against overload and short-circuit || earth fault protection || protection against phase failure and phase imbalance
Tripping Threshold
14.2 x Ir +/- 20 %
Product Compatibility
power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12ES || reversing contactor breaker LU2B32ES
Product Specific Application
basic protection and advanced functions, communication
Network Frequency
40...60 Hz
Load Type
3-phase motor self-cooled
Device Application
motor control || motor protection
Device Short Name
LUCD

Modele CAD

traceparts
traceparts
Pobierz