Schneider Electric

XPSMCMEN0200HT

1 / 1
thumbnail

Beschreibung

Aktiv Reif
This Modicon MCM safe speed monitoring module has 2 HTL encoder inputs (with RJ45 connectors) and 2 proximity sensor inputs (connection via terminal) and is fitted with captive screw clamp terminals. It is designed to monitor zero speed control, max speed (limited speed), speed range and direction. It has a rated supply voltage of 24V DC. It offers up to four logically selectable limited speed thresholds (freely configurable via SoSafe Configurable software) for each logical intput (axis), and a maximum input frequency of 500kHz (for encoders) and 5kHz for proximity sensors. It completes your safety CPU with safe-speed monitoring function, ideal for cutting machines like band-saw, circular saw and grinding machines. This module figures LEDs on its front face, displaying the status (power supply, reset, internal or external errors, node address, encoder or proximity sensors connection status, speed monitoring status). The safe speed monitoring module is connected to the safety controller via the backplane expansion connector. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. This module can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PL = e conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL 3 conforming to IEC 62061. The modular safety controllers Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe speed monitoring module instals on Omega 35mm DIN rail conforming to EN 50022, and is connected to the safety controller via the backplane expansion connector. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Country of Origin
IT
Part Number
XPSMCMEN0200HT
Tariff Code
85371098
EAN
3606480748745
UNSPSC
32151802
Zahlungsmethoden:
Bestes Angebot von:
SKVertrauenswürdiger Automa.Net Lieferant
Verfügbarkeit:
10 Stk.
Auf Lager
Aktualisiert am: 08-11-2024
Garantie:
12 Monate
Geschätzte Lieferung:
Auf Anfrage
Zustand:
Neu versiegelt ab Werk
Neu versiegelt ab Werk - Ein brandneuer, unbenutzter, ungeöffneter, unbeschädigter Artikel in seiner original vom Hersteller versiegelten Verpackung.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1409010EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1409010EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Specifications

Range Of Product
Preventa Safety automation
Discrete Input Voltage
24 V DC
Product Or Component Type
safe speed monitoring module
[Us] Rated Supply Voltage
24 V - 20...20 % DC
Electrical Connection
screw terminal
Function Of Module
speed monitoring
Device Short Name
XPSMCM

Complementary

Connections - Terminals
2 captive screw clamp terminals, removable terminal block || 1 captive screw clamp terminals, removable terminal block
Number Of Terminal Blocks
4
Height
99 mm
Electrical Connection
1 connector RJ45 EIA/TIA-568-A
Integrated Connection Type
backplane expansion bus
Cable Cross Section
0.2-2.5 mm² - AWG 24...AWG 14 flexible without cable end || 0.2-2.5 mm² - AWG 24...AWG 14 solid without cable end || 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, with bezel || 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, without bezel || 0.2-1.5 mm² - AWG 24...AWG 16 flexible without cable end || 0.25-1 mm² - AWG 23...AWG 18 flexible with cable end, without bezel || 0.5-1.5 mm² - AWG 20...AWG 16 flexible with cable end, with double bezel || 0.2-1 mm² - AWG 24...AWG 18 solid without cable end
Power Consumption In W
3 W
Local Signalling
1 LED green PWR power ON || 1 LED green RUN RUN (status) || 1 LED red E IN internal error || 1 LED red E EX external error || 2 LEDs orange ADDR node address || 2 LEDs yellow PROX proximity sensors connection status || 2 LEDs yellow SH speed monitoring status || 2 LEDs yellow ENC encoder connection status
Net Weight
0.3 kg
Maximum Input Frequency
5 kHz sensor || 300 kHz encoder HTL
Power Dissipation In W
3 W
Quality Labels
CE
Mounting Support
omega 35 mm DIN rail EN 50022
Sensor Type
inductive proximity sensor
Width
114.5 mm
Depth
22.5 mm
Safety Level
can reach category 4 ISO 13849-1 || can reach PL = e ISO 13849-1 || type 4 IEC 61496-1 || SILCL 3 IEC 62061

Environment

Product Certifications
cULus || TÜV || RCM
Standards
IEC 62061 || ISO 13849-1 || IEC 61508 || IEC 61496-1 || IEC 61800-5-1
Pollution Degree
2
Ambient Air Temperature For Operation
-10-55 °C
Electromagnetic Compatibility
electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3 || susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
Shock Resistance
10 gn 16 ms) 1000 shocks on each axis IEC 61496-1
Vibration Resistance
+/-0.35 mm 10-55 Hz)IEC 61496-1
[Uimp] Rated Impulse Withstand Voltage
4 kV IEC 61800-5
Ip Degree Of Protection
IP20 enclosure)
Ambient Air Temperature For Storage
-20-85 °C
Service Life
20 year(s)
Relative Humidity
10-95 %
Overvoltage Category
II
Insulation
250 V AC between power supply and housing IEC 61800-5-1

CAD Models

traceparts
traceparts
Herunterladen