Schneider Electric
XSDJ607339
1 / 1
Beschreibung
Aktiv Reif
- Country of Origin
- FR
- Part Number
- XSDJ607339
- Tariff Code
- 85365019
- EAN
- 3389110622799
- UNSPSC
- 39122230
Zahlungsmethoden:
- Bestes Angebot von:
- Vertrauenswürdiger Automa.Net Lieferant
- Verfügbarkeit:
- 1 Stk.Auf LagerAktualisiert am: 08-11-2024
- Garantie:
- 12 Monate
- Geschätzte Lieferung:
- Auf Anfrage
- Zustand:
- Neuer Überschuss
Neuer Überschuss - Ein neuer, unbenutzter, unbeschädigter Artikel ohne Herstellergarantie. Der Artikel kann ohne Originalverpackung oder in Ersatzverpackung geliefert werden. Wenn vorhanden, könnte die Verpackung geöffnet worden sein.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen
Specifications
- Electrical Connection
- screw-clamp terminals
- [Us] Rated Supply Voltage
- 12...48 V DC
- Discrete Output Type
- NPN
- Discrete Output Function
- 1 NO + 1 NC
- Type Of Output Signal
- discrete
- Range Of Product
- Telemecanique Inductive proximity sensors XS
- Sensor Name
- XSD
- Size
- 40 mm
- Wiring Technique
- 4-wire
- Ip Degree Of Protection
- IP67
- Series Name
- general purpose
- Body Type
- fixed
- [Sn] Nominal Sensing Distance
- 60 mm
- Sensor Type
- inductive proximity sensor
- Sensor Design
- form 80 x 80 x 40
- Enclosure Material
- Plastic
Contractual warranty
- Warranty
- 18 months
Complementary
- Height
- 100 mm
- Cable Entry
- 1 entry tapped for Pg 13.5 cable gland
- Marking
- CE
- Material
- plastic
- Switching Frequency
- <= 50 Hz
- Detector Flush Mounting Acceptance
- non flush mountable
- Switching Capacity In Ma
- <= 200 mA
- Detection Face
- frontal
- Width
- 80 mm
- Front Material
- plastic
- Depth
- 40 mm
- Output Circuit Type
- DC
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP071001EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CCC
- Ambient Air Temperature For Operation
- -25-70 °C
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges