Weidmuller

1989210000

BHF 5.00/03/180LH BK/OR
1989210000
1989210000
1989210000
1989210000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.
Offer with manufacturer lead time
Ships in:On Request
Best price:
€2.55

Additional Information

Part Number
1989210000

Rated Data Acc. To Ul 1059

Institute (cURus)
cURus
Certificate No. (cURus)
E60693
Rated voltage (Use group B / UL 1059)
300 V
Rated voltage (Use group C / UL 1059)
50 V
Rated voltage (Use group D / UL 1059)
300 V
Rated current (Use group B / UL 1059)
10 A
Rated current (Use group C / UL 1059)
10 A
Rated current (Use group D / UL 1059)
10 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max.
AWG 14
Reference to approval values
Specifications are maximum values, details - see approval certificate.

Approvals

Approvals
CSA, cURus
UL File Number Search
E60693

Dimensions And Weights

Length
14.6 mm
Length (inches)
0.575 inch
Width
17.5 mm
Width (inches)
0.689 inch
Depth
30.82 mm
Depth (inches)
1.213 inch
Net weight
6.91 g

Rated Data Acc. To Iec

Tested acc. to standard
IEC 60664-1, IEC 61984
Rated current, min. number of poles (Tu=20°C)
10 A
Rated current, min. number of poles (Tu=40°C)
9 A
Rated voltage for surge voltage class / pollution degree II/2
400 V
Rated voltage for surge voltage class / pollution degree III/2
320 V
Rated voltage for surge voltage class / pollution degree III/3
250 V
Rated impulse voltage for surge voltage class/ pollution degree II/2
4 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2
4 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3
4 kV
Clearance, min.
3 mm
Creepage distance, min.
3.2 mm

Material Data

Insulating material
PA 66 GF 30
Colour
black
Colour of operational elements
orange
Material of operational elements
PBT
Colour chart (similar)
RAL 9011
Insulating material group
II
Comparative Tracking Index (CTI)
≥ 400
Insulation strength
≥ 108 Ω
UL 94 flammability rating
V-0
Contact material
Copper alloy
Contact surface
tinned
Storage temperature, min.
-40 °C
Storage temperature, max.
85 °C
Max. relative humidity during storage
80 %
Operating temperature, min.
-40 °C
Operating temperature, max.
120 °C
Temperature range, installation, min.
-25 °C
Temperature range, installation, max.
120 °C

Classifications

ETIM 6.0
EC002638
ETIM 7.0
EC002638
EClass 9.0
27-44-03-09
EClass 9.1
27-44-03-09
EClass 10.0
27-44-03-09

System Specifications

Product family
OMNIMATE Signal - series BL/SL 5.00
Type of connection
Field connection
Pitch in mm (P)
5 mm
Pitch in inches (P)
0.197 inch
Number of poles
3
L1 in mm
10 mm
L1 in inches
0.394 inch
Number of rows
1
Pin series quantity
1
Can be coded
Yes
Plugging cycles
25

Notes

IPC conformity
Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.

Rated Data Acc. To Csa

Institute (CSA)
CSA
Certificate No. (CSA)
200039-70153051
Rated voltage (Use group B / CSA)
300 V
Rated voltage (Use group C / CSA)
50 V
Rated voltage (Use group D / CSA)
300 V
Rated current (Use group B / CSA)
10 A
Rated current (Use group C / CSA)
10 A
Rated current (Use group D / CSA)
10 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max.
AWG 14
Reference to approval values