Weidmuller
7760054306
ACT20P-VM-AO-S
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:On Request
Best price:
€117.89
Additional Information
- Part Number
- 7760054306
General Data
- Accuracy
- 0.5 % FSR
- Configuration
- With FDT/DTM software
- Galvanic isolation
- 3-way isolator, between input ⁄ output ⁄ supply
- Power consumption
- ≤ 100 mA @ 24 VDC, ≤ 120mA @ 24V AC
- Rail
- TS 35
- Step response time
- < 300 ms
- Temperature coefficient
- ≤ 200 ppm/K
- Voltage supply
- 24…240 VUC (±10%)
Approvals
- Approvals
- CE, EAC
- ROHS
- Conform
Dimensions And Weights
- Width
- 22.5 mm
- Width (inches)
- 0.886 inch
- Height
- 119.2 mm
- Height (inches)
- 4.693 inch
- Depth
- 114.3 mm
- Depth (inches)
- 4.5 inch
- Net weight
- 110 g
Connection Data
- Type of connection
- Screw connection
- Tightening torque, min.
- 0.4 Nm
- Tightening torque, max.
- 0.6 Nm
- Clamping range, rated connection
- 1.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, max.
- 2.5 mm²
- Wire connection cross section AWG, min.
- AWG 26
- Wire connection cross section AWG, max.
- AWG 12
Input
- Number of inputs
- 1
- Input signal
- UDC, UACEffective value (sinusoidal only) 40-60 Hz
- Input voltage
- 0…30 V DC, 0…60 V DC, 0…150 V DC, 0…300 V DC, 0…440 V DC, 0…660 V DC, 0…60 V AC, 0…144 V AC, 0…300 V AC, 0…440 V AC
- Input resistance
- 1 MΩ±5%
Classifications
- ETIM 6.0
- EC002653
- ETIM 7.0
- EC002653
- EClass 9.0
- 27-21-01-20
- EClass 9.1
- 27-21-01-20
- EClass 10.0
- 27-21-01-20
Output
- Number of outputs
- 1
- Output voltage, note
- 0...10 V
- Output current
- 0(4)...20 mA
- Load impedance voltage
- ≥ 10 kΩ
- Load impedance current
- ≤ 500 Ω
Product Information
- Product information
- The analogue voltage converter ACT20P-VM-AO-S measures DC or AC voltages. The analogue input signal is linearly converted into an analogue output signal (current or voltage) and galvanically isolated. Features Configuration and monitoring are performed via FDT/DTM-Software „WI-Manager“. Signal and alarm triggering upon exceeding limit values or reverse polarity DC input voltage Front LED indicates operation status 3-way galvanic isolation between input, output and power supply.
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- EMC standards
- IEC 61000-6 /-2, IEC 61000-6-4, IEC 61326-1
- Galvanic isolation
- 3-way isolator, between input ⁄ output ⁄ supply
- Impulse withstand voltage
- 4 kV (1.2 / 50 μs) input - output/ supply, 6 kV (input - output), 1.2/50 µs
- Insulation voltage input or output/supply
- 2.2 kVAC, 1 min, 50 Hz
- Pollution severity
- 2
- Rated voltage
- 300 VAC (supply-output), 500 VAC (supply-input; input-output)
- Surge voltage category
- III
Temperatures
- Humidity
- 5...95 %, no condensation
- Operating temperature, max.
- 65 °C
- Operating temperature, min.
- -25 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -25 °C...65 °C
- Storage temperature
- -40 °C...85 °C
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther