6XV1873-3DN10
SIMATIC NET FO TRAILING CABLE GP 50/125. PREASSEMBLED WITH 2X2 BFOC CONNECTORS. LENGTH 10 M
SIMATIC NET FO TRAILING CABLE GP 50/125. PREASSEMBLED WITH 2X2 BFOC CONNECTORS. LENGTH 10 M
- Neu1 Stk.
Filter
SIMATIC NET FO TRAILING CABLE GP 50/125. PREASSEMBLED WITH 2X2 BFOC CONNECTORS. LENGTH 10 M
SIMATIC NET FO TRAILING CABLE GP 50/125. PREASSEMBLED WITH 2X2 BFOC CONNECTORS. LENGTH 10 M
MCB UL489 2-POLE 25A D-TRIP TYPE NSJ MINIATURE CIRCUIT-BREAKER 240 V 10 KA, 2-POLE, D, 25 A, D=70 MM ACC. TO UL 489
MCB UL489 2-POLE 25A D-TRIP TYPE NSJ MINIATURE CIRCUIT-BREAKER 240 V 10 KA, 2-POLE, D, 25 A, D=70 MM ACC. TO UL 489
Load feeder fuseless reversing duty, AC 400V, sz s00, 0.45...0.63a, DC 24v screw connection for rail-mounting, type of coordination 2, iq = 150ka (also fulfills type of coordination 1) 1NC (contactor)
Load feeder fuseless reversing duty, AC 400V, sz s00, 0.45...0.63a, DC 24v screw connection for rail-mounting, type of coordination 2, iq = 150ka (also fulfills type of coordination 1) 1NC (contactor)
TERMINAL ALPHA FIX 8WH-UL94-V0_GREY
TERMINAL ALPHA FIX 8WH-UL94-V0_GREY
T-F MEMBRANE KEYBOARD IP 65 TOUCHPAD (INT.)
T-F MEMBRANE KEYBOARD IP 65 TOUCHPAD (INT.)
Analog monitoring relay phase sequence monitoring 3x 360 to 520V AC 50 to 60 HZ 2 changeover contacts spring loaded connection
Analog monitoring relay phase sequence monitoring 3x 360 to 520V AC 50 to 60 HZ 2 changeover contacts spring loaded connection
SIMATIC S7-400, UR1 RACK, CENTRALIZED AND DISTRIBUTED WITH 18 SLOTS 2 REDUNDANT PS PLUGGABLE
SIMATIC S7-400, UR1 RACK, CENTRALIZED AND DISTRIBUTED WITH 18 SLOTS 2 REDUNDANT PS PLUGGABLE
O.m.r. key-operated switch, 22mm, round, plastic, lock no. 73034, black, with 2 keys, 2 switch positions o-i, latching, ACt. an. 50 deg., 12/2 o clock, key removal pos. o
O.m.r. key-operated switch, 22mm, round, plastic, lock no. 73034, black, with 2 keys, 2 switch positions o-i, latching, ACt. an. 50 deg., 12/2 o clock, key removal pos. o
SIMATIC STEP 7 Prof. V15 Powerpack Basic V15 -> Professional V15 floating license download; engineering software in TIA PORTAL; software. documentation and license key for download; class A; 6 languages: GE.EN.IT.FR.ES.ZN; executable under Windows 7 (64BIT). Windows 10 (64 Bit). Windows Server 2012/2016 (64); for configuration of SIMATIC S7-1200/1500. SIMATIC S7-300/400/WinAC. SIMATIC Basic Panels email address is mandatory for delivery
SIMATIC STEP 7 Prof. V15 Powerpack Basic V15 -> Professional V15 floating license download; engineering software in TIA PORTAL; software. documentation and license key for download; class A; 6 languages: GE.EN.IT.FR.ES.ZN; executable under Windows 7 (64BIT). Windows 10 (64 Bit). Windows Server 2012/2016 (64); for configuration of SIMATIC S7-1200/1500. SIMATIC S7-300/400/WinAC. SIMATIC Basic Panels email address is mandatory for delivery
SINAMICS V20 1AC200-240V -15/+10% 47-63HZ RATED POWER 3kW WITH 150% OVERLOAD FOR 60SEC INTEGRATED FILTER C1 I/O-INTERFACE: 4DI. 2DO.2AI.1AO FIELDBUS: USS/ MODBUS RTU WITH INBUILT BOP PROTECTION: IP20/ UL OPEN TYPE SIZE:FSAD 176.5x136x160(HXWXD)
SINAMICS V20 1AC200-240V -15/+10% 47-63HZ RATED POWER 3kW WITH 150% OVERLOAD FOR 60SEC INTEGRATED FILTER C1 I/O-INTERFACE: 4DI. 2DO.2AI.1AO FIELDBUS: USS/ MODBUS RTU WITH INBUILT BOP PROTECTION: IP20/ UL OPEN TYPE SIZE:FSAD 176.5x136x160(HXWXD)
SIRIUS soft starter 200-480 V 38 A, 24 V AC/DC Screw terminals
SIRIUS soft starter 200-480 V 38 A, 24 V AC/DC Screw terminals
WINCC/DATAMONITOR V7.3, POWERPACK FROM 1 TO 3 CLIENTS, SINGLE LICENSE, LICENSE KEY ON USB STICK
WINCC/DATAMONITOR V7.3, POWERPACK FROM 1 TO 3 CLIENTS, SINGLE LICENSE, LICENSE KEY ON USB STICK
SIMATIC WINCC RC UPGRADE FROM V7.X TO V7.4 FOR SIMATIC WINCC RUNTIME <(>&<)> CONFIGURATION (RC) INCL. OPTIONS REDUNDANCY. SERVER. USER ARCHIVE. WEB NAVIGATOR. WEB NAV LOAD-BALANCING. WEB DIAG CLIENT/SERVER. DATA MONITOR. CONNECTIVITY PACK. CONNECTIVITY STATION. RUNTIME <(>&<)> CONFIGURATION -SW ON DVD. SINGLE LICENSE. LICENSE KEY ON USB-STICK
SIMATIC WINCC RC UPGRADE FROM V7.X TO V7.4 FOR SIMATIC WINCC RUNTIME <(>&<)> CONFIGURATION (RC) INCL. OPTIONS REDUNDANCY. SERVER. USER ARCHIVE. WEB NAVIGATOR. WEB NAV LOAD-BALANCING. WEB DIAG CLIENT/SERVER. DATA MONITOR. CONNECTIVITY PACK. CONNECTIVITY STATION. RUNTIME <(>&<)> CONFIGURATION -SW ON DVD. SINGLE LICENSE. LICENSE KEY ON USB-STICK
1/2 KIT . REAR TERMINALS FOR CABLES THREE-POLE S6 800 - T6 800
1/2 KIT . REAR TERMINALS FOR CABLES THREE-POLE S6 800 - T6 800
IP66 SWITCHBOARD OPAQUE DOOR-SIZE 3;IP66 SWITCHBOARD OPAQUE DOOR-SIZE 3
IP66 SWITCHBOARD OPAQUE DOOR-SIZE 3;IP66 SWITCHBOARD OPAQUE DOOR-SIZE 3
UPRIGHTS-SIZE 1 Gemini IP66 Insulating switchboards accessories
UPRIGHTS-SIZE 1 Gemini IP66 Insulating switchboards accessories
CT MAX 300 is used to transform primary currents to../5A secondary currents for c.a. measurement instruments
CT MAX 300 is used to transform primary currents to../5A secondary currents for c.a. measurement instruments
The M3SS7-10B Selector Switch is: 3-position - Maintained - Short handle - Black - Non-illuminated - Black Plastic - No contact block
The M3SS7-10B Selector Switch is: 3-position - Maintained - Short handle - Black - Non-illuminated - Black Plastic - No contact block
System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space.
System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space.