AGC-10-R
- Neu22828 Stk.
- Neu Versiegelt2628 Stk.
Filter
OFAA1GG100 HRC Fuse Link Size NH1, gG
OFAA1GG100 HRC Fuse Link Size NH1, gG
The 10x38 gR cylindrical is a fast acting, full range fuse used in the protection of inverters, UPS, variable speed drives and other discrete semiconductor devices.
The 10x38 gR cylindrical is a fast acting, full range fuse used in the protection of inverters, UPS, variable speed drives and other discrete semiconductor devices.
The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
FUSE LINK,LV HRC,35A,660VAC,250VDC SIZE 000, 35A, AC 690V/DC 250V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE LINK,LV HRC,35A,660VAC,250VDC SIZE 000, 35A, AC 690V/DC 250V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE-LINK SITOR 25A,AC690V (GR.000) 25A , AC 690 V ,(SIZE 000) UTILIZ. CATEGORY GR, DIN 43620 SITOR FUSE-LINK
FUSE-LINK SITOR 25A,AC690V (GR.000) 25A , AC 690 V ,(SIZE 000) UTILIZ. CATEGORY GR, DIN 43620 SITOR FUSE-LINK
CYL FUSE,10A,10 X 38 SIZE 10X38MM, 500V 10A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
CYL FUSE,10A,10 X 38 SIZE 10X38MM, 500V 10A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
SITOR CYL FUSE LNK AR 6A,660V AC/700V DC SITOR CYLINDRICAL FUSE LINK AR 6 A, 660 V AC/700 V DC
SITOR CYL FUSE LNK AR 6A,660V AC/700V DC SITOR CYLINDRICAL FUSE LINK AR 6 A, 660 V AC/700 V DC
OFAF000H63 HRC Fuse Link Size NH000, gG
OFAF000H63 HRC Fuse Link Size NH000, gG
Switch Fuses,Front Operated,3-pole,12 (Between the Poles),DIN,0,1,2,Handle and shaft included,
Switch Fuses,Front Operated,3-pole,12 (Between the Poles),DIN,0,1,2,Handle and shaft included,
Engineered to protect photovoltaic applications Mersen's HP10M photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for constant temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10M, designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen's HelioProtection fuse line.
Engineered to protect photovoltaic applications Mersen's HP10M photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for constant temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10M, designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen's HelioProtection fuse line.