- Electrical Connection
- 2 connectors 28 pins
- Current Per Channel
- 0.4 A
- Number Of Outputs
- 1 pulse output || 2 auxiliary output
- Insulation Resistance
- > 10 MOhm
- Product Certifications
- CE || UL || CSA || RCM || EAC || Merchant Navy || ATEX zone 2/22 || IECEx zone 2/22
- Response Time
- < 200 µs for position completed input and drive ready input || < 60 µs for origin input and proximity input
- Current Consumption
- 35 mA 24 V DC preactuator || 150 mA 3.3 V DC typical || 200 mA 3.3 V DC maximum
- Discrete Output Current
- 50 mA
- Current State 0 Guaranteed
- <= 1.5 mA
- Voltage State 0 Guaranteed
- 5 V
- Load Impedance Ohmic
- 15000 Ohm
- Input Current
- 4.3 mA
- Current State 1 Guaranteed
- >= 2 mA
- Operating Threshold
- > 12 V no error supply voltage || > 8 V error supply voltage
- Output Short-Circuit Protection
- by current limiter and electronic circuit breaker
- Output Voltage Limits
- 19...30 V
- Insulation Between Channels
- no insulated
- Input Voltage
- 24 V DC
- Insul Btwn Prim And Second
- 1500 Vrms
- Local Signalling
- for module operating (RUN) 1 LED (green) || for external fault (I/O) 1 LED (red) || for internal fault, module failure (ERR) 1 LED (red) || for download (DL) 1 LED (green) || for channel status (CH00) 8 LEDs (green) || for channel status (CH01) 8 LEDs (green)
- Output Overload Protection
- by current limiter and electronic circuit breaker
- Output Voltage
- 24 V DC
- Module Format
- standard
- Reverse Polarity Protection
- by reverse mounting diode on output || integrated on input
- [Ures] Residual Voltage
- 0.15 V at state 1
- Maximum Leakage Current
- 0.05 mA at state 0
- Preactuator Voltage Detection Threshold
- < 8 V error preactuator voltage auxiliary output || < 8 V no error preactuator voltage auxiliary output || > 14 V error preactuator voltage pulse output || > 14 V no error preactuator voltage pulse output
- Response Time On Output
- 1.2...1.5 ms on appearance || 1.2...1.5 ms on disappearance
- Voltage State 1 Guaranteed
- >= 11 V