- Number Of Devices Per Segment
- 0-32 character mode) || 0-32 Modbus)
- Integrated Connection Type
- non isolated serial link RJ45 character mode asynchronous in baseband, RS232C 2 twisted shielded pairs 0.3...19.2 kbit/s full duplex || non isolated serial link RJ45 character mode asynchronous in baseband, RS485 1 twisted shielded pair 0.3...19.2 kbit/s half duplex || non isolated serial link RJ45, master/slave Modbus, RTU/ASCII asynchronous in baseband, RS232C 1 twisted shielded pair 0.3...19.2 kbit/s half duplex || non isolated serial link RJ45, master/slave Modbus, RTU/ASCII asynchronous in baseband, RS485 1 twisted shielded pair 0.3...19.2 kbit/s half duplex || USB port 12 Mbit/s
- Status Led
- 1 LED (Green) processor running (RUN) || 1 LED (Red) I/O module fault (I/O) || 1 LED (Red) memory card fault (CARD ERR) || 1 LED (Red) processor or system fault (ERR) || 1 LED (Yellow) activity on Modbus (SER COM)
- Communication Module Processor Capacity
- 2 Ethernet communication module || 2 AS-Interface module
- Requests
- 1 K data bytes per request character mode || 252 data bytes per RTU request Modbus || 504 data bytes per ASCII request Modbus
- Supply
- internal power supply via rack
- Default Size Of Object Areas
- 128 %KWi constant words located internal data || 256 %Mi located internal bits || 512 %MWi internal words located internal data
- Marking
- CE
- Current Consumption
- 72 mA 24 V DC
- Net Weight
- 0.2 kg
- Application Structure
- 1 periodic fast task || 32 event tasks || 1 cyclic/periodic master task || no auxiliary task
- System Overhead
- 0.2 ms fast task || 1.05 ms master task
- Maximum Size Of Object Areas
- 128 kB unlocated internal data || 16250 %Mi located internal bits || 32464 %MWi internal words located internal data || 32760 %KWi constant words located internal data
- Maximum Tap Links Length
- <15 m serial link non isolated character mode segment || <15 m serial link non isolated Modbus segment || <40 m serial link isolated character mode segment || <40 m serial link isolated Modbus segment
- Number Of Devices
- 2 point-to-point character mode || 2 point-to-point Modbus
- Execution Time Per Instruction
- 0.18 µs Boolean || 0.26 µs double-length words || 0.38 µs single-length words || 1.74 µs floating points
- Control Parameter
- one CRC on each frame (RTU) Modbus || one LRC on each frame (ASCII) character mode || one LRC on each frame (ASCII) Modbus
- Number Of Addresses
- 0-248 character mode || 0-248 Modbus
- Number Of Instructions Per Ms
- 4.2 Kinst/ms 65 % Boolean + 35 % fixed arithmetic || 5.4 Kinst/ms 100 % Boolean
- Bus Length
- 0-10 m serial link non isolated character mode segment || 0-10 m serial link non isolated Modbus segment || 0-1000 m serial link isolated character mode segment || 0-1000 m serial link isolated Modbus segment || 0-15 m character mode point-to-point || 0-15 m Modbus point-to-point
- Memory Description
- internal RAM 2048 kB || internal RAM 128 kB data || internal RAM 1792 kB program constants and symbols || supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data
- Control Channels
- programmable loops