Schneider Electric
LD4LD030BD
Contactor breaker, TeSys Integral 63, 3P, 63A, 690VAC 50/60Hz, AC-1/AC-43, 24VDC coil
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Produktbedingungen:
Angebot mit Herstellervorlaufzeit
Lieferung:Auf Anfrage
Bester Preis:
€831.56
Additional Information
- Part Number
- LD4LD030BD
- UNSPSC
- 39121529
- Country of Origin
- FR
Specifications
- Product Or Component Type
- contactor breaker
- Product Name
- TeSys Integral 63
- Range
- TeSys
- Device Short Name
- LD4LD
Contractual warranty
- Warranty
- 18 months
Complementary
- [Ics] Rated Service Breaking Capacity
- 10 kA 600...690 V IEC 60947-2 || 35 kA 480...525 V IEC 60947-2 || 50 kA <= 440 V IEC 60947-2
- [Ue] Rated Operational Voltage
- 690 V AC 50/60 Hz
- [Uc] Control Circuit Voltage
- 24 V DC
- Height
- 243 mm
- Control Circuit Voltage Limits
- 0.25...0.7 Uc drop-out 55 °C || 0.85...1.1 Uc operation 55 °C
- [Ith] Conventional Free Air Thermal Current
- 63 A 40 °C
- Maximum Breaking Time
- 4 ms
- Hold-In Power Consumption In W
- 8-8 W 20 °C
- Irms Rated Making Capacity
- 756 A IEC 60947-4 || 946 A IEC 60947-4
- Net Weight
- 3.8 kg
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV IEC 60947-4
- Connections - Terminals
- power circuit screw clamp terminals 1 6-50 mm² flexible - without cable end || power circuit screw clamp terminals 2 6-25 mm² flexible - without cable end || power circuit screw clamp terminals 1 6-25 mm² flexible - with cable end || power circuit screw clamp terminals 2 6-25 mm² flexible - with cable end || power circuit screw clamp terminals 1 6-50 mm² solid
- Thermal Stress Limit
- 300000 A².s
- Utilisation Category
- AC-43 || AC-1
- [Ie] Rated Operational Current
- 63 A AC AC-1 || 63 A AC AC-43
- Electrical Durability
- 1 Mcycles AC-3 3 kA 415 V - after 1 cycle O-CO-r-CO at Isc || 0.9 Mcycles AC-3 10 kA 415 V - after 1 cycle O-CO-r-CO at Isc || 0.6 Mcycles AC-3 25 kA 415 V - after 1 cycle O-CO-r-CO at Isc || 0.5 Mcycles AC-3 35 kA 415 V - after 1 cycle O-CO-r-CO at Isc || 0.2 Mcycles AC-3 50 kA 415 V - after 1 cycle O-CO-r-CO at Isc
- Breaking Capacity
- Icu 10 kA 600...690 V 0.5 ) IEC 60947-2 || Icu 30 kA 480...525 V 0.25 ) IEC 60947-6-2 || Icu 50 kA <= 440 V 0.25 ) IEC 60947-2
- Operating Time
- 15...25 ms DC opening 20 °C control circuit || 25...40 ms DC closing 20 °C control circuit
- [Ui] Rated Insulation Voltage
- 690 V IEC 60947-1
- Tightening Torque
- power circuit 6 N.m screw clamp terminals
- Control Type
- knob emergency stop Red front CNOMO
- Mechanical Durability
- 1.2 Mcycles
- Inrush Power In W
- 300-300 W 20 °C)
- Poles Description
- 3P
- [Ipk] Rated Peak Withstand Current
- 105 kA IEC 60947-2
- Test Function
- self test
- Width
- 90 mm
- Depth
- 192 mm
- Motor Power Kw
- 15 kW 220...240 V AC 50/60 Hz || 30 kW 400 V AC 50/60 Hz || 33 kW 415 V AC 50/60 Hz || 37 kW 500 V AC 50/60 Hz || 55 kW 660 V AC 50/60 Hz || 33 kW 440 V AC 50/60 Hz
- Heat Dissipation
- 5-5 W 32 A per pole, hot state power circuit || 7-7 W 50 A per pole, hot state power circuit || 9-9 W 63 A per pole, hot state power circuit || 4.4-4.4 W 25 A per pole, hot state power circuit || 5.8-5.8 W 40 A per pole, hot state power circuit
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive
- Compliant
Environment
- Product Certifications
- ASEFA || NKK || LROS (Lloyds register of shipping) || GL || SCC || ASE || DNV || BV || SETI || DEMKO || OVE || USSR || RINA || ASTA || CSA || NEMKO || UL
- Mechanical Robustness
- vibrations de-energised3 Gn, 1...300 Hz || vibrations energised3 Gn, 1...300 Hz || shocks de-energised8 Gn for 11 ms || shocks energised8 Gn for 11 ms
- Ambient Air Temperature For Operation
- -20-60 °C
- Standards
- NF C 20-040 || IEC 60947-4 || NF C 63-130 || NEN || VDE 0110 || VDE 0660 || BS 5424 || IEC 60364 || IEC 60158-1 || NF C 63-650 || IEC 60947-1 || VDE 0113 || IEC 60947-2 || VDE 0170 || BS 4941 || IEC 60204-2 || NF C 63-110 || IEC 60204-1 || VDE 0171 || NF C 63-120 || NBN || VDE 0100 || VDE 471 || NF C 79-100 || BS 4752
- Ip Degree Of Protection
- IP20 B conforming to IEC 60144 || IP20 B conforming to IEC 60529
- Ambient Air Temperature For Storage
- -40-80 °C
- Operating Altitude
- 9842.52 ft (3000 m) without derating
- Protective Treatment
- TH
Dokumente
Data Sheet
HerunterladenCAD Models
traceparts
HerunterladenAndere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges