Aktiv Reif
This product is part of the XY2C range, an offer of emergency stop rope pull switches. This emergency stop rope pull switch has 1 NC and 1 NO, slow break contacts with the positive opening operation. The switch with a rated operating current of 3A at 240V AC, 0.27A at 250V DC and conventional enclosed thermal current of 10A. It is furnished with screw clamp terminals for electrical connection and 3 plain holes for PG13.5 or ISO M20 cable gland. The trigger cable anchor point at right and left hand sides. It offers long mechanical durability of about 60,000 operating cycles. It is an IP66 rated product. The casing is made of Zamak (red) with stainless steel cover. It weighs 1.9kg. It is suitable for woodworking machines, conveyor systems, printing machines, textile machines, rolling mills, test laboratories and surface treatment works. This product is certified by CE, CSA, CCC, EAC and UL. It meets CSA C22.2 No 14, EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/IEC 60204-1 and UL 508 standards. The XY2 line of switches come in a robust metal enclosure so they can be used in severe environments and they conform to EN/ISO 13850 and EN/IEC 60947-5-5. XY2 range emergency stop rope pull switch is intended for all machines requiring stopping of a dangerous movement in the immediate vicinity of the machine.
Country of Origin
MA
Part Number
XY2CEDA297
Tariff Code
85365080
EAN
3606480880018
UNSPSC
39122213
Zahlungsmethoden:
Bestes Angebot von:
SKVertrauenswürdiger Automa.Net Lieferant
Verfügbarkeit:
10 Stk.
Auf Lager
Aktualisiert am: 08-11-2024
Garantie:
12 Monate
Geschätzte Lieferung:
Auf Anfrage
Zustand:
Neu versiegelt ab Werk
Neu versiegelt ab Werk - Ein brandneuer, unbenutzter, ungeöffneter, unbeschädigter Artikel in seiner original vom Hersteller versiegelten Verpackung.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen

Specifications

Range Of Product
Telemecanique Emergency stop rope pull switches XY2C
Product Or Component Type
dual emergency stop rope pull switch
Housing Colour
red RAL 3000
Overvoltage Category
class I EN/IEC 61140
Device Short Name
XY2CED

Complementary

Reset
by booted push-button
Number Of Cables
2
Terminals Description Iso N°1
(13-14)NO || (21-22)NC
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60269
Bellow Material
nitril
Positive Opening
with EN/IEC 60947-5-1
[Ithe] Conventional Enclosed Thermal Current
10 A
Marking
CE
Local Signalling
with pilot light, yellow, 230 V
Net Weight
1.9 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Trigger Cable Maximum Length
2 x 100 m
Connections - Terminals
screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Contacts Type And Composition
2 x (1 NC + 1 NO)
[Ui] Rated Insulation Voltage
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operation
slow-break
Distance Between Cable Supports
3-5 m
Mechanical Durability
60000 cycles
Cable Entry Number
3 plain hole Pg 13.5 or ISO M20 cable gland
Compatibility Code
XY2CED
Body Material
zamak
Trigger Cable Anchor Point
RH and LH sides
Safety Reliability Data
B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Cover Material
stainless steel
Tightening Torque
0.8-1.2 N.m
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111159EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation
-25-70 °C
Standards
CSA C22.2 No 14 || EN/IEC 60947-5-1 || EN/IEC 60947-5-5 || EN/ISO 13850 || work equipment directive 2009/104/EC || EN/IEC 60204-1 || machinery directive 2006/42/EC || UL 508
Product Certifications
UL category NISD emergency stop devices || CSA || CCC || EAC
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
10 gn 10-300 Hz)EN/IEC 60068-2-6
Ip Degree Of Protection
IP66 IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Protective Treatment
TC