Schneider Electric
XZBWR2STT24
Programmable receiver, 4 PNP, 200 mA, 24 V DC, 2 pusbuttons, 6 LEDs
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Produktbedingungen:
Angebot mit Herstellervorlaufzeit
Lieferung:1 - 2 Viele Arbeitstage
Bester Preis:
Preisanfrage senden
Additional Information
- Part Number
- XZBWR2STT24
- Tariff Code
- 8517620090
Specifications
- Product Or Component Type
- programmable receiver
- Product Compatibility
- radio transmitter XZBWE
- Device Application
- interface to PLC
Complementary
- [Us] Rated Supply Voltage
- 24 V DC - 15...20 %
- Minimum Switching Current
- 10 mA
- Height
- 108 mm
- Maximum Switching Current
- 200 mA DC
- Short-Circuit Protection
- 1 A fuse fast blow
- [Uimp] Rated Impulse Withstand Voltage
- 0.8 kV
- Status Led
- 1 LED Green power ON || 1 LED green and yellow reception signal || 4 LEDs Green output active
- Output Contacts
- 4 PNP
- Electrical Connection
- 1 conductor cable 0.14-2.5 mm² AWG 26...AWG 14 solid without cable end IEC 60947-1 || 2 conductors cable 0.14-1.5 mm² AWG 26...AWG 16 solid without cable end IEC 60947-1 || 1 conductor cable 0.14-4 mm² AWG 26...AWG 12 flexible with cable end IEC 60947-1 || 2 conductors cable 0.14-1.5 mm² AWG 26...AWG 16 flexible with cable end IEC 60947-1
- Communication Port Protocol
- Zigbee green power 2.4 GHz
- Response Time
- < 30 ms after sensor change
- Marking
- CE
- Operating Position
- any position without derating
- Starting Time
- <= 400 ms
- Utilisation Category
- DC-13 EN/IEC 60947-5-1
- Net Weight
- 0.13 kg
- Maximum Voltage Drop
- <2 V 200 mA)
- Time Delay Range
- 0.5 s - 15...15 %)
- Nominal Output Current
- 0.8 A 24 V DC
- Rated Short-Duration Power Frequency Withstand Voltage
- 1 kV 50 Hz EN/IEC 60947-5-1
- Maximum Sensing Distance
- 100 m in free field || 25 m in a metal enclosure
- Breaking Capacity
- 4.8 W per output)
- Maximum Number Of Transceivers
- ZigBee <2
- Mounting Support
- 35 mm symmetrical DIN rail conforming to EN/IEC 60715 || mounting plate
- Housing Material
- self-extinguishing plastic
- Function Of Module
- receiver unit for remote sensor
- Width
- 36 mm
- Output Type
- transistor PNP
- Depth
- 75 mm
- Tightening Torque
- 0.5-1 N.m EN/IEC 60947-1
- Maximum Power Consumption In W
- 26 W DC
- Number Of Channels
- 2 per receiver
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Standards
- EN/IEC 60947-5-1 || EN/IEC 60947-1
- Shock Resistance
- 10 gn 16 ms) 6000 shocks IEC 60068-2-27
- Vibration Resistance
- +/- 7.5 mm 5-14 Hz)IEC 60068-2-6 || 2 gn 8-150 Hz)IEC 60068-2-6
- Insulation Resistance
- > 500 MOhm 500 V DC NF C 20-030
- Ip Degree Of Protection
- IP20 IEC 60529 casing) || IP20 IEC 60529 terminals)
- Electromagnetic Compatibility
- immunity for industrial environments conforming to EN/IEC 61000-6-2 || conducted emission conforming to ETSI EN 301 489-17 || radiated emission conforming to ETSI EN 300 328 || electrical fast transient/burst immunity test 1 kV PNP output wires conforming to IEC 61000-4-4 || 1.2/50 µs shock waves immunity test 0.5 kV differential mode conforming to IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 1 kV common mode conforming to IEC 61000-4-5 || immunity to microbreaks and voltage drops 7 ms conforming to IEC 61000-4-11 || conducted and radiated emissions class B conforming to CISPR 22 || electrostatic discharge immunity test 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 || electrostatic discharge immunity test 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m, 80 MHz...1 GHz at 3 m conforming to IEC 61000-4-3 || susceptibility to electromagnetic fields 3 V/m, 1.4 MHz…2 GHz at 3 m conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test 2 kV power supply wires conforming to IEC 61000-4-4 || conducted RF disturbances 10 V conforming to IEC 61000-4-6 || radiated emission conforming to ETSI EN 301 489-17
- Pollution Degree
- 2 IEC 60664-1
- Surge Withstand
- 0.5 kV differential mode IEC 61000-4-5 || 1 kV common mode IEC 61000-4-5
- Ambient Air Temperature For Storage
- -40-70 °C
- Overvoltage Category
- III IEC 60664-1
- Relative Humidity
- 90-90 % -20-55 °C, without condensation ETSI EN 300 328
- [Ui] Rated Insulation Voltage
- 60 V IEC 60664-1