Schneider Electric
XZBWR2STT24
1 / 1
Descrizione
Attivo maturo
This product is part of the XC Standard range, an offer of limit switches. This programmable receiver is equipped with 2 buttons and 6 LED indicators (power ON, reception signal and output active). It has 4 PNP output contacts and has 2.4GHz ZigBee green power communication port protocol. It is available with 1A fuse type fast blow short-circuit protection. It is a programmable receiver with nominal output current of 0.8A at 24V DC, maximum switching current of 200mA DC, rated supply voltage of 24V DC and maximum power consumption of 26W DC. Receiver unit has 2 channels per receiver. It supports 35mm symmetrical DIN rail mount conforming to EN/IEC 60715, mounting plate. It is an IP20 rated product. The programmable receiver is made of self-extinguishing plastic. Its dimensions are 36mm (Width) x 75mm (Depth) x 108mm (Height) and weighs 0.13kg. It is used for interface to PLC applications. This product is certified by CE. It meets EN/IEC 60947-5-1 and EN/IEC 60947-1 standards. It is compatible with radio transmitter XZBWE112A24. Limit switches for contact sensing of inflexible objects. High quality of products and worldwide availability guarantee in a short delivery time. A comprehensive offer of contacts for a simpler and safer machine design. Ex OsiSwitch, IEC standard format limit switches consist of products designed according to EN 50047, EN 50041 as well as popular XCM and XCKM miniature and classic limit switches ranges.- Country of Origin
- FR
- Part Number
- XZBWR2STT24
- Tariff Code
- 85176200
- EAN
- 3389119623964
Metodi di pagamento:
- Migliore offerta da:
- Fornitore Automa.Net di fiducia
- Disponibilità:
- 1 pz.DisponibileAggiornato il: 21-10-2024
- Consegna stimata:
- Su richiesta
- Condizione:
- Nuove eccedenze
Nuove eccedenze - Un articolo nuovo, inutilizzato e non danneggiato senza garanzia del produttore. L'articolo può arrivare senza confezione originale o in una confezione sostitutiva. Se fornita, la scatola potrebbe essere stata aperta.
Processo di Pagamento Sicuro
Politiche di Reso e Rimborso
Politiche di Spedizione
Politiche di Garanzia
Specifications
- Product Or Component Type
- programmable receiver
- Product Compatibility
- radio transmitter XZBWE
- Device Application
- interface to PLC
Complementary
- [Us] Rated Supply Voltage
- 24 V DC - 15...20 %
- Minimum Switching Current
- 10 mA
- Height
- 108 mm
- Maximum Switching Current
- 200 mA DC
- Short-Circuit Protection
- 1 A fuse fast blow
- [Uimp] Rated Impulse Withstand Voltage
- 0.8 kV
- Status Led
- 1 LED Green power ON || 1 LED green and yellow reception signal || 4 LEDs Green output active
- Output Contacts
- 4 PNP
- Electrical Connection
- 1 conductor cable 0.14-2.5 mm² AWG 26...AWG 14 solid without cable end IEC 60947-1 || 2 conductors cable 0.14-1.5 mm² AWG 26...AWG 16 solid without cable end IEC 60947-1 || 1 conductor cable 0.14-4 mm² AWG 26...AWG 12 flexible with cable end IEC 60947-1 || 2 conductors cable 0.14-1.5 mm² AWG 26...AWG 16 flexible with cable end IEC 60947-1
- Communication Port Protocol
- Zigbee green power 2.4 GHz
- Response Time
- < 30 ms after sensor change
- Marking
- CE
- Operating Position
- any position without derating
- Starting Time
- <= 400 ms
- Utilisation Category
- DC-13 EN/IEC 60947-5-1
- Net Weight
- 0.13 kg
- Maximum Voltage Drop
- <2 V 200 mA)
- Time Delay Range
- 0.5 s - 15...15 %)
- Nominal Output Current
- 0.8 A 24 V DC
- Rated Short-Duration Power Frequency Withstand Voltage
- 1 kV 50 Hz EN/IEC 60947-5-1
- Maximum Sensing Distance
- 100 m in free field || 25 m in a metal enclosure
- Breaking Capacity
- 4.8 W per output)
- Maximum Number Of Transceivers
- ZigBee <2
- Mounting Support
- 35 mm symmetrical DIN rail conforming to EN/IEC 60715 || mounting plate
- Housing Material
- self-extinguishing plastic
- Function Of Module
- receiver unit for remote sensor
- Width
- 36 mm
- Output Type
- transistor PNP
- Depth
- 75 mm
- Tightening Torque
- 0.5-1 N.m EN/IEC 60947-1
- Maximum Power Consumption In W
- 26 W DC
- Number Of Channels
- 2 per receiver
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Standards
- EN/IEC 60947-5-1 || EN/IEC 60947-1
- Shock Resistance
- 10 gn 16 ms) 6000 shocks IEC 60068-2-27
- Vibration Resistance
- +/- 7.5 mm 5-14 Hz)IEC 60068-2-6 || 2 gn 8-150 Hz)IEC 60068-2-6
- Insulation Resistance
- > 500 MOhm 500 V DC NF C 20-030
- Ip Degree Of Protection
- IP20 IEC 60529 casing) || IP20 IEC 60529 terminals)
- Electromagnetic Compatibility
- immunity for industrial environments conforming to EN/IEC 61000-6-2 || conducted emission conforming to ETSI EN 301 489-17 || radiated emission conforming to ETSI EN 300 328 || electrical fast transient/burst immunity test 1 kV PNP output wires conforming to IEC 61000-4-4 || 1.2/50 µs shock waves immunity test 0.5 kV differential mode conforming to IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 1 kV common mode conforming to IEC 61000-4-5 || immunity to microbreaks and voltage drops 7 ms conforming to IEC 61000-4-11 || conducted and radiated emissions class B conforming to CISPR 22 || electrostatic discharge immunity test 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 || electrostatic discharge immunity test 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m, 80 MHz...1 GHz at 3 m conforming to IEC 61000-4-3 || susceptibility to electromagnetic fields 3 V/m, 1.4 MHz…2 GHz at 3 m conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test 2 kV power supply wires conforming to IEC 61000-4-4 || conducted RF disturbances 10 V conforming to IEC 61000-4-6 || radiated emission conforming to ETSI EN 301 489-17
- Pollution Degree
- 2 IEC 60664-1
- Surge Withstand
- 0.5 kV differential mode IEC 61000-4-5 || 1 kV common mode IEC 61000-4-5
- Ambient Air Temperature For Storage
- -40-70 °C
- Overvoltage Category
- III IEC 60664-1
- Relative Humidity
- 90-90 % -20-55 °C, without condensation ETSI EN 300 328
- [Ui] Rated Insulation Voltage
- 60 V IEC 60664-1