ABB
1SBL157001R1401
AF12-30-01-14 250-500V50/60HZ-DC Contactor
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
€15.06
1
Formas de pago:
Un total de 301 Parts In-Stock de 12 Distributors
Condiciones del producto:
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€17.61
Additional Information
- Part Number
- 1SBL157001R1401
- UNSPSC
- 39121529
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Power contactor, AC switching
- Class Code : EC000066
- Version : 7
Dimensions
- Product Net Width
- 45 mm
- Product Net Depth / Length
- 77 mm
- Product Net Height
- 86 mm
- Product Net Weight
- 0.31 kg
Technical
- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 0
- Number of Auxiliary Contacts NC
- 1
- Standards
- IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
- Rated Operational Voltage
- Auxiliary Circuit 690 VMain Circuit 690 V
- Rated Frequency (f)
- Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 Aacc. to IEC 60947-5-1, Θ = 40 °C 16 A
- Rated Operational Current AC-1 (Ie)
- (690 V) 40 °C 28 A(690 V) 60 °C 28 A(690 V) 70 °C 24 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 60 °C 12 A(440 V) 60 °C 12 A(500 V) 60 °C 12.5 A(690 V) 60 °C 9 A(380 / 400 V) 60 °C 12 A(220 / 230 / 240 V) 60 °C 12 A
- Rated Operational Current AC-3e (Ie)
- (415 V) 60 °C 12 A(440 V) 60 °C 12 A(500 V) 60 °C 12.5 A(690 V) 60 °C 9 A(380 / 400 V) 60 °C 12 A(220 / 230 / 240 V) 60 °C 12 A
- Rated Operational Power AC-3 (Pe)
- (400 V) 5.5 kW(415 V) 5.5 kW(440 V) 5.5 kW(500 V) 7.5 kW(690 V) 7.5 kW(380 / 400 V) 5.5 kW(220 / 230 / 240 V) 3 kW
- Rated Operational Power AC-3e (Pe)
- (415 V) 5.5 kW(440 V) 5.5 kW(500 V) 7.5 kW(690 V) 7.5 kW(380 / 400 V) 5.5 kW(220 / 230 / 240 V) 3 kW
- Rated Operational Current AC-15 (Ie)
- (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 Afor 0.1 s 140 Afor 1 s 100 A
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
- Maximum Electrical Switching Frequency
- (AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-2 / AC-4) 300 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour
- Rated Operational Current DC-1 (Ie)
- (110 V) 1-Pole, 40 °C 15 A(110 V) 1-Pole, 60 °C 15 A(110 V) 1-Pole, 70 °C 15 A(110 V) 2 Poles in Series, 40 °C 27 A(110 V) 2 Poles in Series, 60 °C 27 A(110 V) 2 Poles in Series, 70 °C 24 A(110 V) 3 Poles in Series, 40 °C 27 A(110 V) 3 Poles in Series, 60 °C 27 A(110 V) 3 Poles in Series, 70 °C 24 A(220 V) 2 Poles in Series, 40 °C 15 A(220 V) 2 Poles in Series, 60 °C 15 A(220 V) 2 Poles in Series, 70 °C 15 A(220 V) 3 Poles in Series, 40 °C 27 A(220 V) 3 Poles in Series, 60 °C 27 A(220 V) 3 Poles in Series, 70 °C 24 A(72 V) 1-Pole, 40 °C 27 A(72 V) 1-Pole, 60 °C 27 A(72 V) 1-Pole, 70 °C 24 A(72 V) 2 Poles in Series, 40 °C 27 A(72 V) 2 Poles in Series, 60 °C 27 A(72 V) 2 Poles in Series, 70 °C 24 A(72 V) 3 Poles in Series, 40 °C 27 A(72 V) 3 Poles in Series, 60 °C 27 A(72 V) 3 Poles in Series, 70 °C 24 A
- Rated Operational Current DC-3 (Ie)
- (110 V) 1-Pole, 40 °C 7 A(110 V) 1-Pole, 60 °C 7 A(110 V) 1-Pole, 70 °C 7 A(110 V) 2 Poles in Series, 40 °C 27 A(110 V) 2 Poles in Series, 60 °C 27 A(110 V) 2 Poles in Series, 70 °C 24 A(110 V) 3 Poles in Series, 40 °C 27 A(110 V) 3 Poles in Series, 60 °C 27 A(110 V) 3 Poles in Series, 70 °C 24 A(220 V) 2 Poles in Series, 40 °C 7 A(220 V) 2 Poles in Series, 60 °C 7 A(220 V) 2 Poles in Series, 70 °C 7 A(220 V) 3 Poles in Series, 40 °C 27 A(220 V) 3 Poles in Series, 60 °C 27 A(220 V) 3 Poles in Series, 70 °C 24 A(72 V) 1-Pole, 40 °C 27 A(72 V) 1-Pole, 60 °C 27 A(72 V) 1-Pole, 70 °C 24 A(72 V) 2 Poles in Series, 40 °C 27 A(72 V) 2 Poles in Series, 60 °C 27 A(72 V) 2 Poles in Series, 70 °C 24 A(72 V) 3 Poles in Series, 40 °C 27 A(72 V) 3 Poles in Series, 60 °C 27 A(72 V) 3 Poles in Series, 70 °C 24 A
- Rated Operational Current DC-5 (Ie)
- (110 V) 1-Pole, 40 °C 4 A(110 V) 1-Pole, 60 °C 4 A(110 V) 1-Pole, 70 °C 4 A(110 V) 2 Poles in Series, 40 °C 15 A(110 V) 2 Poles in Series, 60 °C 15 A(110 V) 2 Poles in Series, 70 °C 15 A(110 V) 3 Poles in Series, 40 °C 27 A(110 V) 3 Poles in Series, 60 °C 27 A(110 V) 3 Poles in Series, 70 °C 24 A(220 V) 2 Poles in Series, 40 °C 4 A(220 V) 2 Poles in Series, 60 °C 4 A(220 V) 2 Poles in Series, 70 °C 4 A(220 V) 3 Poles in Series, 40 °C 12 A(220 V) 3 Poles in Series, 60 °C 12 A(220 V) 3 Poles in Series, 70 °C 12 A(72 V) 1-Pole, 40 °C 12 A(72 V) 1-Pole, 60 °C 12 A(72 V) 1-Pole, 70 °C 12 A(72 V) 2 Poles in Series, 40 °C 27 A(72 V) 2 Poles in Series, 60 °C 27 A(72 V) 2 Poles in Series, 70 °C 24 A(72 V) 3 Poles in Series, 40 °C 27 A(72 V) 3 Poles in Series, 60 °C 27 A(72 V) 3 Poles in Series, 70 °C 24 A
- Rated Operational Current DC-13 (Ie)
- (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 690 Vacc. to IEC 60947-5-1 690 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- 6 kV
- Maximum Mechanical Switching Frequency
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc)
- 50 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V
- Operate Time
- Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting by Screws (not supplied)
- 2 x M4 screws placed diagonally
- Connecting Capacity Main Circuit
- Flexible with Ferrule 1/2x 0.75 ... 6 mm²Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Rigid Solid 1/2x 1 ... 4 mm²Rigid Stranded 1/2x 1 ... 6 mm²
- Connecting Capacity Auxiliary Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
- Connecting Capacity Control Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
- Wire Stripping Length
- Auxiliary Circuit 10 mmControl Circuit 10 mmMain Circuit 10 mm
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type
- Screw Terminals
Classifications
- Object Classification Code
- Q
- ETIM 4
- EC000066 - Magnet contactor, AC-switching
- ETIM 5
- EC000066 - Magnet contactor, AC-switching
- EClass
- V11.0 : 27371003
- IDEA Granular Category Code (IGCC)
- 4758 >> Iec Contactors
- E-Number (Finland)
- 3706226
- E-Number (Sweden)
- 3211367
Environmental
- Ambient Air Temperature
- Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
- Climatic Withstand
- Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6
- 5 ... 300 Hz 4 g closed position / 2 g open position
- Resistance to Shock acc. to IEC 60068-2-27
- Closed, Shock Direction: B1 25 gOpen, Shock Direction: B1 5 gShock Direction: A 30 gShock Direction: B2 15 gShock Direction: C1 25 gShock Direction: C2 25 g
- RoHS Status
- Following EU Directive 2011/65/EU
Technical UL/CSA
- NEMA Size
- 0
- Continuous Current Rating NEMA
- 18 A
- Horsepower Rating NEMA
- (115 V AC) Single Phase 1 Hp(200 V AC) Three Phase 3 Hp(230 V AC) Single Phase 2 Hp(230 V AC) Three Phase 3 Hp(460 V AC) Three Phase 5 Hp(575 V AC) Three Phase 5 Hp
- Maximum Operating Voltage UL/CSA
- Main Circuit 600 V
- General Use Rating UL/CSA
- (600 V AC) 28 A
- Horsepower Rating UL/CSA
- (120 V AC) Single Phase 1 hp(200 ... 208 V AC) Three Phase 3 hp(220 ... 240 V AC) Three Phase 3 hp(240 V AC) Single Phase 2 hp(440 ... 480 V AC) Three Phase 7-1/2 hp(550 ... 600 V AC) Three Phase 10 hp
- Connecting Capacity Main Circuit UL/CSA
- Rigid Solid 1/2x 16-10 AWGRigid Stranded 1/2x 16-10 AWG
- Connecting Capacity Auxiliary Circuit UL/CSA
- Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
- Connecting Capacity Control Circuit UL/CSA
- Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
- Tightening Torque UL/CSA
- Auxiliary Circuit 11 in·lbControl Circuit 11 in·lbMain Circuit 13 in·lb
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900
Otras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros