- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 1
- Number of Auxiliary Contacts NC
- 1
- Rated Operational Voltage
- Main Circuit 1000 V
- Rated Frequency (f)
- Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A
- Rated Operational Current AC-1 (Ie)
- (1000 V) 40 °C 700 A(1000 V) 55 °C 600 A(1000 V) 60 °C 600 A(1000 V) 70 °C 480 A(690 V) 40 °C 700 A(690 V) 55 °C 600 A(690 V) 70 °C 480 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 55 °C 460 A(440 V) 55 °C 460 A(500 V) 55 °C 460 A(690 V) 55 °C 400 A(1000 V) 55 °C 200 A(380 / 400 V) 55 °C 460 A(220 / 230 / 240 V) 55 °C 460
- Rated Operational Power AC-3 (Pe)
- (415 V) 250 kW(440 V) 250 kW(500 V) 315 kW(690 V) 355 kW(1000 V) 280 kW(380 / 400 V) 250 kW(220 / 230 / 240 V) 132 kW
- Rated Breaking Capacity AC-3
- 8 x Ie AC-3
- Rated Making Capacity AC-3
- 10 x Ie AC-3
- Short-Circuit Protective Devices
- gG Type Fuses 800 A
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
- Maximum Electrical Switching Frequency
- (AC-1) 300 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 300 cycles per hour
- Rated Operational Current DC-1 (Ie)
- (110 V) 1-Pole, 40 °C 700 A(110 V) 2 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 40 °C 700 A
- Rated Operational Current DC-3 (Ie)
- (110 V) 1-Pole, 40 °C 700 A(110 V) 2 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 40 °C 700 A
- Rated Operational Current DC-5 (Ie)
- (110 V) 1-Pole, 40 °C 700 A(110 V) 2 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 40 °C 700 A
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- Main Circuit 8 kV
- Mechanical Durability
- 3 million
- Maximum Mechanical Switching Frequency
- 300 cycles per hour
- Coil Operating Limits
- (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
- Rated Control Circuit Voltage (Uc)
- DC Operation 24 ... 60 V
- Coil Consumption
- Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 900 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 900 V·APull-in at Max. Rated Control Circuit Voltage DC 900 V·A
- Operate Time
- Between Coil De-energization and NC Contact Closing 45 ... 55 msBetween Coil De-energization and NO Contact Opening 48 ... 58 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms
- Connecting Capacity Main Circuit
- Bar 47 mm²Rigid Al-Cable 2x240 mm²Rigid Cu-Cable 240 mm²
- Connecting Capacity Auxiliary Circuit
- Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 1x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Terminal Type
- Main Circuit: Bars