ABB
1SFL657001R9103
AF1350-30-01E 100-250V ac/dc Contactor
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Additional Information
- Part Number
- 1SFL657001R9103
- UNSPSC
- 39121529
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Power contactor, AC switching
- Class Code : EC000066
- Version : 7
Dimensions
- Product Net Width
- 438 mm
- Product Net Depth / Length
- 244 mm
- Product Net Height
- 392 mm
- Product Net Weight
- 32 kg
Technical
- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 1
- Number of Auxiliary Contacts NC
- 0
- Rated Operational Voltage
- Main Circuit 1000 V
- Rated Operational Current AC-1 (Ie)
- (1000 V) 40 °C 1350 A(1000 V) 55 °C 1150 A(1000 V) 70 °C 1000 A(690 V) 40 °C 1350 A(690 V) 55 °C 1150 A(690 V) 70 °C 1000 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 55 °C 860 A(440 V) 55 °C 860 A(500 V) 55 °C 800 A(690 V) 55 °C 800 A(1000 V) 55 °C 375 A(380 / 400 V) 55 °C 860 A(220 / 230 / 240 V) 55 °C 860
- Rated Operational Power AC-3 (Pe)
- (415 V) 500 kW(440 V) 560 kW(500 V) 560 kW(690 V) 800 kW(1000 V) 560 kW(380 / 400 V) 475 kW(220 / 230 / 240 V) 257 kW
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 1000 V
- Rated Control Circuit Voltage (Uc)
- 50 Hz 100 ... 250 V
- Coil Consumption
- Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 48 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·APull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
- Terminal Type
- Main Circuit: Bars
Classifications
- Object Classification Code
- Q
- ETIM 4
- EC000066 - Magnet contactor, AC-switching
- ETIM 5
- EC000066 - Magnet contactor, AC-switching
- EClass
- V11.0 : 27371003
- IDEA Granular Category Code (IGCC)
- 4755 >> Contactors
Environmental
- RoHS Status
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Technical UL/CSA
- Maximum Operating Voltage UL/CSA
- Main Circuit 1000 V
- General Use Rating UL/CSA
- (1000 V AC) 1350 A(600 V AC) 1350 A
- Horsepower Rating UL/CSA
- (220 ... 240 V AC) Three Phase 400 Hp(440 ... 480 V AC) Three Phase 800 Hp(550 ... 600 V AC) Three Phase 1000 Hp
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900
Otras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros