NS... contactor relays are used for switching auxiliary circuits and control circuits. - Poles: 8-pole contactor relays (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor relay side) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
Part Number
NS44E-25M
UNSPSC
39121500
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Contactor relay
Class Code : EC000196
Version : 7
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Solicite un presupuesto y le enviaremos información sobre disponibilidad y precio.

Dimensions

Product Net Width
45 mm
Product Net Depth / Length
100.2 mm
Product Net Height
68 mm
Product Net Weight
0.26 kg

Technical

Number of Auxiliary Contacts NO
4
Number of Auxiliary Contacts NC
4
Standards
IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage
Auxiliary Circuit 690 VMain Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 Afor 1 s 100 A
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W
Rated Insulation Voltage (Ui)
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 220 V60 Hz 220 V
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 22 msBetween Coil De-energization and NO Contact Opening 5 ... 19 msBetween Coil Energization and NC Contact Opening 6 ... 18 msBetween Coil Energization and NO Contact Closing 9 ... 24 ms
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 9 mmControl Circuit 9 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal Type
Screw Terminals

Classifications

Object Classification Code
K
ETIM 4
EC000196 - Contactor relay
ETIM 5
EC000196 - Contactor relay
EClass
V11.0 : 27371001
IDEA Granular Category Code (IGCC)
4755 >> Contactors

Environmental

Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6
5 ... 300 Hz 3 g Closed position / 2 g Open position
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: C1 19 gClosed, Shock Direction: C2 16 gOpen, Shock Direction: C1 8 gOpen, Shock Direction: C2 13 gShock Direction: A 20 gShock Direction: B1 5 gShock Direction: B2 15 g
RoHS Status
Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lbControl Circuit 9 in·lb

Ordering

Minimum Order Quantity
20 piece
Customs Tariff Number
85364900