Specifications for the TS100 PRO
- Maximum Length
- 8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable types, and 500 feet (152 meters) on cables with high loss. The tester shows -Err if the cable is too long to be correctly measured.
- Representative Maximum Cable Length
- 8,000 feet (2,438 meters): CAT-3 Twisted Pair || 1,500 feet (457 meters): RG-174/U Coax || 8,000 feet (2,438 meters): CAT-5 Twisted Pair || 3,000 feet (900 meters): RG-6/U TV Coax || 6,000 feet (1,830 meters): 12/2 AC Wire
- Minimum Length
- No minimum length (can read a bridge tap at 0 feet/meters). Minimum non-zero reading is 2 feet or 1 meter.
- Length Accuracy
- ±2 feet (±0. 6 m) for cables less than 10 feet (3 m) || ±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m) || +/-3%+/-5 feet (±2 m) for cables longer than 200 feet (60 m)
- Distance to Bridge Tap
- 0 feet to 3,200 feet (975 meters)
- Minimum Length of Bridge Tap
- 10% of the distance to the bridge tap. Dependent on the cable characteristics.
- Measurement Rate
- Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.
- VOP
- Adjustable from 20 to 99, saved in flash memory.
- Test Technology
- Time Domain Reflectometry (TDR) with 100 Ω drive impedance, 6v maximum pulse height.
- Cable Type
- Virtually all two or more conductor cables.
- Power
- 4 AA alkaline batteries.
- Reverse Battery Protection
- No damage to the tester will occur if the batteries are installed backwards.
- Battery Life
- 35 hours (typical)
- Low Battery Indication
- LED display alternates between LO and bAtt when the battery voltage falls below 4. 5v.
- Maximum Output Voltage
- 4 voltage peak
- Maximum Isolation Voltage
- 250 volts RMS
- Voltage Measurements
- Accuracy: AC: +/-1%+/-2 volts (45 Hz to 65 Hz); DC: +/-1%+/-2 volts DC || Range: 0 volts AC to 115 volts AC; 0 volts DC to ±150 volts DC
- High Voltage Detection
- AC voltage detected to 115 volts; DC voltage detected to ±150 volts. || AC voltage ≥90 volts or DC voltage ≥100 volts causes high voltage warnings to show on the display
- SmartTone® (5-tones) Range
- 7,000 feet (2,134 meters)
- Toner Range
- 52,800 feet (16,093 meters)
- Tone Injection
- Approximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristics change as cable condition changes to “normal-open” from any other condition.
- Impedance Range
- 35 Ω to 330 Ω with auto-compensation within this range. Cables with impedances outside this range will not be properly tested and may produce erratic or incorrect readings.
- Temperature Range
- Storage: 32°F to 131°F (0°C to 55°C) || Operating: 32°F to 104°F (0°C to 40°C)
- Humidity
- Storage: 0% to 100% relative humidity || Operating: 20% to 80% relative humidity
- Operating Humidity
- 50% maximum at 104°F (40°C ) || 80% maximum at 86°F (30°C )
- Operating Altitude
- 9,843 ft max (3,000 m max)
- Weight
- 1 lb (454 grams)
- Dimensions
- 7. 4 in x 2. 7 in x 1. 4 in (18. 8 cm x 6. 9 cm x 3. 6 cm)
- Safety
- EMC: IEC/EN61326-1:2006 || IEC 61010-1:2010; N10140
- Certifications and Compliance
- Conforms to relevant European Union directives || IEC/EN61010-1 CAN/CSA-C22. 2 No. 1010. 1-92 + CSA-C22. 2 No. 1010. 1B-97, UL/ANSI 3111-1 || Conforms to relevant Australian standards
Otras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPC industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros