Fluke
190-102
1.25 GS/s sampling rate, 100MHz bandwidth with 2 input channels and DMM for industrial process control, automation or electronic applications.
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Additional Information
- Part Number
- 190-102
Mechanical and General Specifications
- Li-Ion battery
- BP290 2400 mAh Li-ion battery up to 4 hours included standard
- Warranty
- 3-years on main instrument, 1-year on accessories
- Weight
- 2.2 kg
- Size
- 270 x 190 x 70 mm
DMM Specification
- Memory
- Recording: 10
- Maximum resolution
- 5000 counts
- Memory
- 2 Channel
- Memory
- Screen + Setup: 30
- Display
- 153 mm full color LCD with fast update rate
- Measurements
- VDC, VAC rms, VAC + DC rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature °C or °F (using optional converter)
- Meter inputs (also used as External Trigger Input for the Oscilloscope Mode)
- 4 mm banana inputs, fully isolated from scope inputs and from scope ground
Included Accessories
- Warranty
- Three years on main instrument, one year on accessories
Specifications
- Inputs
- 2 scope plus DMM input
- Maximum record length
- Scope mode: 10,000 pts per input
- Input sensitivity
- 2 mV-100 V/div
- Glitch capture
- 8 ns
- Trigger types
- Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
- Persistence
- Digital persistence giving analog oscilloscope-like waveform decay
- Trigger source
- Any scope input channel, or external via DMM input
- Number of channels
- 100 MHz: 2 channels
- Waveform compare
- Waveform reference with automatic Pass/Fail testing
- Bandwidth
- 100 MHz
- Timebase range
- 5 ns - 2 min/div
- Scope measurements
- Automatic: 30
- Maximum record length
- ScopeRecord mode: 30,000 pts
- Independently floating isolated inputs
- Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
- Real-time sample rate
- 1.25 GS/s
- Scope measurements
- Cursor: 7
Safety Specifications
- Electrical safety
- 1,000V CAT III/600V CAT IV (EN61010-1)
Environmental Specifications
- Operating temperature
- 0°C to 50°C Excluding Batteries
- Operating temperature
- 0°C to 40°C Including Batteries
- Operating altitude
- Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
- Operating altitude
- Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
- Storage temperature
- -20°C to +60°C
Otras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPC industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros