Phoenix Contact
1405900
Sensor/actuator cable - SAC-4P-FS SH SCO BK/.../... - 1405900
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Additional Information
- Part Number
- 1405900
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Sensor-actuator patch cord
- Class Code : EC001855
- Version : 7
PVC yellow 105 °C [542]
- Cable type
- PVC yellow 105 °C
- Cable type (abbreviation)
- 542
- UL AWM style
- 2517 (105 °C / 300 V)
- AWG signal line
- 22
- Conductor structure signal line
- 30x 1.30 mm
- Core diameter including insulation
- 1.27 mm ±0.03 mm
- Wire colors
- brown, blue, black, white
- Overall twist
- 4 wires, twisted
- Shielding
- Tinned copper braided shield
- Optical shield covering
- 85 %
- External sheath, color
- yellow
- External cable diameter D
- 5.5 mm ±0.2 mm
- Minimum bending radius, flexible installation
- 12 x D
- Cable weight
- 48 kg/km
- Outer sheath, material
- PVC
- Material conductor insulation
- PVC
- Conductor material
- Tin-plated Cu litz wires
- Insulation resistance
- ≥ (550 M Ohms/m @ 500V)
- Conductor resistance
- max. 50.5 Ω/km (20 °C)
- Nominal voltage, cable
- 300 V
- Special properties
- UL standards PLTC and ITC
- Flame resistance
- FT4
- Other resistance
- UV resistant
- Ambient temperature (operation)
- -30 °C - 105 °C (cable, fixed installation)
- Ambient temperature (operation)
- -5 °C - 105 °C (cable, flexible installation)
PUR halogen-free yellow [240]
- Cable type
- PUR halogen-free yellow
- Cable type (abbreviation)
- 240
- Cable abbreviation
- Li9YV1-C-V1-11Y
- UL AWM style
- 20549
- Conductor cross section
- 4x 0.34 mm²
- AWG signal line
- 22
- Conductor structure signal line
- 42x 0.10 mm
- Core diameter including insulation
- 1.27 mm ±0.02 mm
- Thickness, insulation
- ≥ 0.21 mm
- Wire colors
- brown, white, blue, black
- Overall twist
- 4 wires, twisted
- Length of twist, overall twist
- 50 mm
- Shielding
- Braided copper wires
- Optical shield covering
- 85 %
- External sheath, color
- yellow
- Outer sheath thickness
- approx. 1 mm
- External cable diameter D
- 5.9 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 5 x D
- Minimum bending radius, flexible installation
- 10 x D
- Number of bending cycles
- 2000000
- Minimum bending radius, drag chain applications
- 10 x D
- Traversing path
- 10 m
- Traversing rate
- 3 m/s
- Acceleration
- 10 m/s²
- Cable weight
- 46 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 1 GΩ*km (at 20 °C)
- Conductor resistance
- 58 Ω/km (at 20 °C)
- Nominal voltage, cable
- ≤ 300 V AC
- Test voltage, cable
- ≥ 3000 V AC (Spark test)
- Test voltage Core/Shield
- ≥ 2000 V AC (for 60 s)
- Flame resistance
- in accordance with UL 758/1581 FT2
- Halogen-free
- in accordance with DIN VDE 0472 part 815
- Halogen-free
- According to EN 50267-2-1
- Resistance to oil
- According to DIN EN 60811-2-1, 168 h at 100°C
- Resistance to oil
- According to UL 758, 168 h at 60°C
- Other resistance
- hydrolysis and microbe resistant
- Other resistance
- Resistant to salt water
- Other resistance
- abrasion-resistant
- Other resistance
- Low adhesion
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -25 °C - 80 °C (cable, flexible installation)
Dimensions
- Length of cable
- Free input (0.2 - 40.0 m)
Black PVC 105°C [535]
- Cable type
- Black PVC 105°C
- Cable type (abbreviation)
- 535
- UL AWM style
- 2517 (105 °C / 300 V)
- AWG signal line
- 22
- Conductor structure signal line
- 30x 1.30 mm
- Core diameter including insulation
- 1.27 mm ±0.03 mm
- Wire colors
- brown, blue, black, white
- Overall twist
- 4 wires, twisted
- Shielding
- Tinned copper braided shield
- Optical shield covering
- 85 %
- External sheath, color
- black
- External cable diameter D
- 5.5 mm ±0.2 mm
- Minimum bending radius, flexible installation
- 12 x D
- Cable weight
- 48 kg/km
- Outer sheath, material
- PVC
- Material conductor insulation
- PVC
- Conductor material
- Tin-plated Cu litz wires
- Nominal voltage, cable
- 300 V
- Special properties
- UL standards PLTC and ITC
- Flame resistance
- FT4
- Other resistance
- UV resistant
- Ambient temperature (operation)
- -30 °C - 105 °C (cable, fixed installation)
Material
- Flammability rating according to UL 94
- HB
- Contact material
- CuSn
- Contact surface material
- Ni/Au
- Contact carrier material
- TPU GF
- Material of grip body
- TPU, hardly inflammable, self-extinguishing
- Material, knurls
- Zinc die-cast, nickel-plated
- Sealing material
- NBR
PUR halogen-free black [PUR]
- Cable type
- PUR halogen-free black
- Cable type (abbreviation)
- PUR
- Cable abbreviation
- Li9Y-V1-C-V1-11Y
- UL AWM style
- 20549 / 10493 (80°C/300 V)
- Conductor cross section
- 4x 0.34 mm² (Signal line)
- AWG signal line
- 22
- Conductor structure signal line
- 42x 0.10 mm
- Core diameter including insulation
- 1.27 mm ±0.02 mm (Signal line)
- Thickness, insulation
- ≥ 0.21 mm
- Wire colors
- brown, white, blue, black
- Overall twist
- 4 wires, twisted
- Shielding
- Tinned copper braided shield
- Optical shield covering
- 80 %
- External sheath, color
- black-gray RAL 7021
- Outer sheath thickness
- approx. 0.5 mm
- External cable diameter D
- 4.95 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 5 x D
- Minimum bending radius, flexible installation
- 10 x D
- Number of bending cycles
- 10000000
- Minimum bending radius, drag chain applications
- 10 x D
- Traversing path
- 10 m
- Traversing rate
- 3 m/s
- Acceleration
- 10 m/s²
- Cable weight
- 36 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 100 GΩ*km (at 20 °C)
- Conductor resistance
- max. 58 Ω/km (at 20 °C)
- Cable capacity
- ≤ 80 pF/m (Conductor-Conductor)
- Cable capacity
- ≤ 135 pF/m (Wire/shield)
- Wave impedance
- ≥ 62 Ω (f = 10 MHz)
- Conductor inductance
- approx. 0.75 mH/km (f = 1 kHz)
- Nominal voltage, cable
- ≤ 300 V
- Test voltage, cable
- ≥ 3000 V
- Special properties
- Flexible cable conduit capable
- Special properties
- Silicone-free
- Special properties
- Free of substances which would hinder coating with paint or varnish
- Special properties
- Low adhesion surface
- Flame resistance
- in accordance with UL 758/1581 FT2
- Flame resistance
- DIN EN 60332-2-2 (20 s)
- Halogen-free
- in accordance with DIN VDE 0472 part 815
- Halogen-free
- in accordance with DIN EN 50267-2-1
- Resistance to oil
- in accordance with DIN EN 60811-2-1
- Other resistance
- Highly resistant to acids, alkaline solutions and solvents
- Other resistance
- hydrolysis and microbe resistant
- Other resistance
- Resistant to salt water
- Other resistance
- partly UV-resistant in accordance with DIN EN ISO 4892-2-A
- Other resistance
- abrasion-resistant
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -25 °C - 80 °C (cable, flexible installation)
Ambient conditions
- Ambient temperature (operation)
- -25 °C - 90 °C (Plug / socket)
- Degree of protection
- IP65
- Degree of protection
- IP67
Environmental Product Compliance
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Standards and Regulations
- Standards/specifications
- M12 connector IEC 61076-2-101
- Flammability rating according to UL 94
- HB
Otras categorías
NanómetrosManómetrosFlujómetrosSensoresSensores de aceleraciónSensores de fibra ópticaDetectoresSensores ultrasónicosSensores de temperatura y humedadSensores de vibraciónSensores de nivelSensores de presiónSensores de proximidadSensores InductivosSensores de movimientoGrupo de Sensores MagnéticosSensores ópticosSensores CapacitivosSensores FotoeléctricosSensores de posiciónCodificadoresOtros Sensores y Accesorios