1 / 1
thumbnail

Descripción

Sensor/actuator cable, 3-position, PE-X halogen-free, black, shielded, Plug angled M12 SPEEDCON, A-coded, on free cable end, cable length: 10 m, For railway applications
Country of Origin
PL
Part Number
1407302
Tariff Code
85444290
EAN
4046356774185
UPC
4046356774185
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Solicite un presupuesto y le enviaremos información sobre disponibilidad y precio.

Dimensions

Length of cable
10 m

Material

Flammability rating according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA 6.6
Material of grip body
PA 6.6
Material, knurls
Zinc die-cast, nickel-plated
Standards/regulations
PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Ambient conditions

Ambient temperature (operation)
-40 °C - 85 °C (Plug / socket)
Degree of protection
IP65

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

Standards and Regulations

Standard designation
M12 connector
Standards/regulations
IEC 61076-2-101
Standard designation
Shock, vibration
Standards/regulations
EN 50155
Flammability rating according to UL 94
V0

Cable

Cable type
Shielded black RADOX®
Cable type (abbreviation)
28R
Conductor cross section
3x 0.5 mm²
AWG signal line
20
Conductor structure signal line
19x 0.18 mm
Core diameter including insulation
1.43 mm
Wire colors
White 1, white 2, white 3
Overall twist
3 wires, twisted
Shielding
Tinned copper braided shield
External sheath, color
black
External cable diameter D
5.3 mm ±0,3 mm
Minimum bending radius, fixed installation
3 x D
Minimum bending radius, flexible installation
4 x D
Cable weight
51 kg/km
Outer sheath, material
PE-X
Material conductor insulation
PE-X
Conductor material
Tin-plated Cu litz wires
Conductor resistance
≤ 40.1 Ω/km
Nominal voltage, cable
600 V AC (Core-ground, U0)
Nominal voltage, cable
1000 V AC (Core-ground, U)
Nominal voltage, cable
≤ 720 V AC (core-ground)
Nominal voltage, cable
≤ 1200 V AC (Core-ground, Um)
Nominal voltage, cable
≤ 900 V DC (Core-ground, V0)
Nominal voltage, cable
≤ 1500 V DC (core-core)
Test voltage, cable
3500 V AC (50 Hz, 5 min.)
Test voltage, cable
8400 V DC (50 Hz, 5 min.)
Fire protection in rail vehicles
BS 6853 (Category Ia, Ib, II)
Fire protection in rail vehicles
GM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehicles
EN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehicles
DIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehicles
NF F16-101 (Category A1, A2, B)
Fire protection in rail vehicles
NF F16-101 (Class C/F0)
Fire protection in rail vehicles
NFPA 130
Fire protection in rail vehicles
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
Flame resistance
EN 50266
Flame resistance
EN 50305, 9.1.2
Flame resistance
NF C32-070, 2.1
Flame resistance
NF C32-070, 2.2
Flame resistance
UL 1685, 12 (FT4)
Flame resistance
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
According to EN 50267-2-1
Resistance to oil
according to IRM 902, 72 h at 100 °C
Other resistance
Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes
BS 6853 D.8.7
Concentration of fumes
EN 61034-2
Concentration of fumes
UL 1685, 12 (FT4)
Fume corrosiveness
EN 50267-2-2
Fume toxicity
BS 6853 B.1
Fume toxicity
EN 50305, 9.2
Ambient temperature (operation)
-50 °C - 120 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 90 °C (cable, flexible installation)

Productos relacionados