Phoenix Contact
1441121
Sensor/actuator cable - SAC-3P-MR-BI-1L-Z180 SCO/.../. - 1441121...
- Part Number
- 1441121
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Additional Information
- Part Number
- 1441121
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Sensor-actuator patch cord
- Class Code : EC001855
- Version : 7
PUR halogen-free gray [280]
- Cable type
- PUR halogen-free gray
- Cable type (abbreviation)
- 280
- Cable abbreviation
- Li9Y11Y-HF
- UL AWM style
- 20549
- Conductor cross section
- 3x 0.5 mm² (Signal line)
- AWG signal line
- 20
- Conductor structure signal line
- 28x 0.15 mm
- Core diameter including insulation
- 1.5 mm ±0.05 mm (Signal line)
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- Wires twisted in layers
- External sheath, color
- gray RAL 7001
- External cable diameter D
- 4.5 mm ±0.2 mm
- Smallest bending radius, fixed installation
- 22.5 mm
- Number of bending cycles
- 15000000
- Bending radius
- 50 mm
- Traversing path
- 0.9 m
- Traversing rate
- 5 m/s
- Acceleration
- 30 m/s²
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 20 MΩ*km
- Conductor resistance
- 39 Ω/km (at 20 °C)
- Nominal voltage, cable
- 300 V
- Test voltage, cable
- 1200 V
- Flame resistance
- according to DIN VDE 0482
- Flame resistance
- According to DIN EN 50265-2-1
- Resistance to oil
- largely oil-resistant
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -20 °C - 80 °C (cable, flexible installation)
PVC black [PVC]
- Cable type
- PVC black
- Cable type (abbreviation)
- PVC
- Cable abbreviation
- LiYY
- UL AWM style
- 2464
- Conductor cross section
- 3x 0.5 mm²
- AWG signal line
- 20
- Conductor structure signal line
- 16x 0.20 mm
- Core diameter including insulation
- 1.5 mm ±0.05 mm
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- 3 wires, twisted
- External sheath, color
- black RAL 9005
- External cable diameter D
- 4.8 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 5 x D
- Outer sheath, material
- PVC
- Material conductor insulation
- PVC
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 20 MΩ*km
- Conductor resistance
- 39 Ω/km (at 20 °C)
- Nominal voltage, cable
- 300 V
- Test voltage, cable
- 1200 V
- Flame resistance
- DIN VDE 0482
- Flame resistance
- DIN EN 50265-2-1
- Resistance to oil
- largely oil-resistant
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -5 °C - 80 °C (cable, flexible installation)
PUR halogen-free yellow [240]
- Cable type
- PUR halogen-free yellow
- Cable type (abbreviation)
- 240
- Cable abbreviation
- Li9Y11Y
- UL AWM style
- 20549 (80°C/300 V)
- Conductor cross section
- 3x 0.5 mm²
- AWG signal line
- 20
- Conductor structure signal line
- 28x 0.15 mm
- Core diameter including insulation
- 1.46 mm ±0.02 mm
- Thickness, insulation
- ≥ 0.21 mm
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- 3 wires, twisted
- External sheath, color
- yellow
- Outer sheath thickness
- approx. 0.6 mm
- External cable diameter D
- 4.5 mm ±0.15 mm
- Cable weight
- 30 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 10 GΩ*km
- Conductor resistance
- ≤ 39 Ω/km
- Nominal voltage, cable
- ≤ 300 V
- Test voltage, cable
- ≥ 3000 V
- Flame resistance
- in accordance with DIN UL-Style 20549
- Halogen-free
- in accordance with DIN VDE 0472 part 815
- Ambient temperature (operation)
- -15 °C - 80 °C (cable, fixed installation)
PUR irradiated halogen-free orange [150]
- Cable type
- PUR irradiated halogen-free orange
- Cable type (abbreviation)
- 150
- Cable abbreviation
- Li12Y11X
- Conductor cross section
- 3x 0.5 mm² (Signal line)
- AWG signal line
- 20
- Conductor structure signal line
- 28x 0.15 mm
- Core diameter including insulation
- 1.46 mm ±0.02 mm (Signal line)
- Thickness, insulation
- ≥ 0.21 mm (Core insulation)
- Thickness, insulation
- approx. 0.6 mm (Outer cable sheath)
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- 3 wires, twisted
- External sheath, color
- orange RAL 2003
- External cable diameter D
- 4.5 mm ±0.15 mm
- Number of bending cycles
- 5000000
- Bending radius
- 45 mm
- Traversing path
- 10 m
- Traversing rate
- 3 m/s
- Cable weight
- 31 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- TPE-E
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 100 MΩ*km (at 20 °C)
- Conductor resistance
- max. 39 Ω/km (at 20 °C)
- Nominal voltage, cable
- ≤ 300 V
- Test voltage, cable
- ≥ 3000 V
- Special properties
- Silicone-free
- Special properties
- Irradiated
- Flame resistance
- in accordance with DIN UL-Style 20549
- Halogen-free
- in accordance with DIN VDE 0472 part 815
- Ambient temperature (operation)
- -25 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -5 °C - 80 °C (cable, flexible installation)
Dimensions
- Length of cable
- Free input (0.2 - 40.0 m)
- Central screw valve connector
- M3 x 29
PVC, 0.75 mm², black [534]
- Conductor cross section
- 3x 0.75 mm² (Signal line)
- AWG signal line
- 18
- Conductor structure signal line
- 24x 0.20 mm
- Core diameter including insulation
- 1.7 mm ±0.1 mm
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- 3 wires, twisted
- External sheath, color
- black
- External cable diameter D
- 5.3 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 5 x D
- Outer sheath, material
- PVC
- Material conductor insulation
- PVC
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- min. 20 MΩ*km (at 20 °C)
- Conductor resistance
- 26 Ω/km (at 20 °C)
- Nominal voltage, cable
- 300 V
- Test voltage, cable
- 1200 V
- Flame resistance
- DIN VDE 0482
- Flame resistance
- DIN EN 50265-2-1
- Flame resistance
- in acc. to UL VW1
- Resistance to oil
- in accordance with DIN EN 60811-2-1
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -5 °C - 80 °C (cable, flexible installation)
Material
- Flammability rating according to UL 94
- HB
- Contact material
- CuSn
- Contact surface material
- Ni/Au
- Contact carrier material
- TPU GF
- Material of grip body
- TPU
- Valve plug contact material
- CuSn
- Valve plug contact surface material
- Sn
- Valve plug contact insert material
- PA 6.6
- Material housing valve plug
- TPU
- Material, knurls
- Zinc die-cast, nickel-plated
- Sealing material
- TPU (Seal molded)
PUR/PVC, 0.75 mm², black [116]
- Cable type
- PUR/PVC, 0.75 mm², black
- Cable type (abbreviation)
- 116
- Cable abbreviation
- LiYY11Y
- UL AWM style
- 20549
- Conductor cross section
- 3x 0.75 mm²
- AWG signal line
- 18
- Conductor structure signal line
- 24x 0.20 mm
- Core diameter including insulation
- 1.7 mm ±0.05 mm
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- 3 wires, twisted
- External sheath, color
- black RAL 9005
- External cable diameter D
- 5.8 mm ±0.2 mm
- Minimum bending radius, flexible installation
- 10 x D
- Number of bending cycles
- 1000000
- Traversing rate
- 2 m/s
- Acceleration
- 2.5 m/s²
- Outer sheath, material
- PUR
- Material, inner sheath
- PVC
- Material conductor insulation
- PVC
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 20 MΩ*km
- Conductor resistance
- 26 Ω/km (at 20 °C)
- Nominal voltage, cable
- 300 V
- Test voltage, cable
- 1200 V
- Special properties
- flexible
- Flame resistance
- DIN VDE 0482
- Flame resistance
- DIN EN 50265-2-1
- Flame resistance
- in acc. with UL FT-2
- Other resistance
- Low adhesion
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -5 °C - 80 °C (cable, flexible installation)
PUR halogen-free black [PUR]
- Cable type
- PUR halogen-free black
- Cable type (abbreviation)
- PUR
- Cable abbreviation
- Li9Y11Y-HF
- UL AWM style
- 20549
- Conductor cross section
- 3x 0.5 mm²
- AWG signal line
- 20
- Conductor structure signal line
- 28x 0.15 mm
- Core diameter including insulation
- 1.5 mm ±0.05 mm (Signal line)
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- 3 wires, twisted
- External sheath, color
- black-gray RAL 7021
- External cable diameter D
- 4.5 mm ±0.2 mm
- Smallest bending radius, fixed installation
- 22.5 mm
- Number of bending cycles
- 15000000
- Bending radius
- 50 mm
- Traversing path
- 0.9 m
- Traversing rate
- 5 m/s
- Acceleration
- 30 m/s²
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- min. 20 MΩ*km
- Conductor resistance
- 39 Ω/km (at 20 °C)
- Nominal voltage, cable
- ≤ 300 V
- Test voltage, cable
- ≥ 1200 V
- Flame resistance
- according to DIN VDE 0482
- Flame resistance
- According to DIN EN 50265-2-1
- Halogen-free
- in accordance with DIN VDE 0472 part 815
- Other resistance
- largely oil-resistant
- Other resistance
- partly UV-resistant in accordance with DIN EN ISO 4892-2-A
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -20 °C - 80 °C (cable, flexible installation)
PUR, halogen-free, highly stranded, resistant to welding sparks, gray [800]
- Note
- Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
- Cable abbreviation
- LiF9Y11Y
- UL AWM style
- 20549
- Conductor cross section
- 3x 0.5 mm² (Signal line)
- AWG signal line
- 20
- Conductor structure signal line
- 28x 0.15 mm
- Core diameter including insulation
- 1.5 mm ±0.05 mm (Signal line)
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- Wires twisted in layers
- External sheath, color
- gray RAL 7001
- External cable diameter D
- 4.5 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 5 x D
- Minimum bending radius, flexible installation
- 5 x D
- Number of bending cycles
- 15000000
- Bending radius
- 50 mm
- Traversing path
- 0.9 m
- Traversing rate
- 5 m/s
- Acceleration
- 30 m/s²
- Torsion force
- ± 360 °/m
- Cable weight
- 31 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- PP
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 20 MΩ*km
- Conductor resistance
- 39 Ω/km (at 20 °C)
- Nominal voltage, cable
- 300 V
- Test voltage, cable
- 1200 V
- Special properties
- Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
- Special properties
- Free from silicone and cadmium
- Special properties
- Free of substances which would hinder coating with paint or varnish
- Flame resistance
- in accordance with UL 758/1581 FT2
- Halogen-free
- The cable is halogen-free
- Resistance to oil
- in accordance with DIN EN 60811-2-1
- Other resistance
- Highly resistant to acids, alkaline solutions and solvents
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -25 °C - 80 °C (cable, flexible installation)
PVC gray [500]
- Cable type
- PVC gray
- Cable type (abbreviation)
- 500
- Cable abbreviation
- LiYY
- Conductor cross section
- 3x 0.5 mm² (Signal line)
- AWG signal line
- 20
- Conductor structure signal line
- 16x 0.20 mm
- Core diameter including insulation
- 1.5 mm ±0.05 mm (Signal line)
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- Wires twisted in layers
- External sheath, color
- gray RAL 7001
- External cable diameter D
- 4.8 mm ±0.2 mm
- Smallest bending radius, fixed installation
- 24 mm
- Outer sheath, material
- PVC
- Material conductor insulation
- PVC
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- min. 20 MΩ*km
- Conductor resistance
- 39 Ω/km (at 20 °C)
- Nominal voltage, cable
- 300 V
- Test voltage, cable
- 1200 V
- Flame resistance
- DIN EN 50265-2-1
- Resistance to oil
- largely oil-resistant
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -5 °C - 80 °C (cable, flexible installation)
Ambient conditions
- Ambient temperature (operation)
- -25 °C - 90 °C (Plug / socket)
- Ambient temperature (operation)
- -20 °C - 80 °C (valve plug)
- Degree of protection
- IP65
- Degree of protection
- IP67
- Degree of protection
- IP68
Line characteristics
- Note
- This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.
Environmental Product Compliance
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
PUR/PVC 0.75 mm² gray [117]
- Cable abbreviation
- LiYY11Y
- UL AWM style
- 20549
- Conductor cross section
- 3x 0.75 mm² (Signal line)
- AWG signal line
- 18
- Conductor structure signal line
- 24x 0.20 mm
- Core diameter including insulation
- 1.7 mm ±0.05 mm (Signal line)
- Wire colors
- black 1, black 2, green/yellow
- Overall twist
- Wires twisted in layers
- External sheath, color
- gray RAL 7001
- External cable diameter D
- 5.8 mm ±0.2 mm
- Smallest bending radius, fixed installation
- 29 mm
- Smallest bending radius, movable installation
- 58 mm
- Number of bending cycles
- 1000000
- Traversing rate
- 2 m/s
- Acceleration
- 2.5 m/s²
- Outer sheath, material
- PUR
- Material, inner sheath
- PVC
- Material conductor insulation
- PVC
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 20 MΩ*km
- Conductor resistance
- 26 Ω/km (at 20 °C)
- Nominal voltage, cable
- 300 V
- Test voltage, cable
- 1200 V
- Flame resistance
- according to DIN VDE 0482
- Flame resistance
- According to DIN EN 50265-2-1
- Flame resistance
- in acc. with UL FT-2
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -5 °C - 80 °C (cable, flexible installation)
Standards and Regulations
- Standards/specifications
- M12 connector IEC 61076-2-101
- Flammability rating according to UL 94
- HB
Otras categorías
NanómetrosManómetrosFlujómetrosSensoresSensores de aceleraciónSensores de fibra ópticaDetectoresSensores ultrasónicosSensores de temperatura y humedadSensores de vibraciónSensores de nivelSensores de presiónSensores de proximidadSensores InductivosSensores de movimientoGrupo de Sensores MagnéticosSensores ópticosSensores CapacitivosSensores FotoeléctricosSensores de posiciónCodificadoresOtros Sensores y Accesorios