Phoenix Contact
1538018
Bus system cable - SAC-5P-FSB SCO/900/... - 1538018
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Pin assignment
- Contact | Color (signal designation) | Contact (optional)
- 1 (Socket) | YE (DO)
- Contact | Color (signal designation) | Contact (optional)
- 2 (Socket) | GN (DO)
- Contact | Color (signal designation) | Contact (optional)
- 3 (Socket) | GY (DI)
- Contact | Color (signal designation) | Contact (optional)
- 4 (Socket) | PK (DI)
- Contact | Color (signal designation) | Contact (optional)
- 5 (Socket) | BN (GND)
Dimensions
- Length of cable
- Free input (0.2 - 40.0 m)
- Stripping length of the free conductor end
- 50 mm
Material
- Flammability rating according to UL 94
- V0
- Contact material
- CuSn
- Contact surface material
- Ni/Au
- Contact carrier material
- PA 6.6
- Material of grip body
- TPU, hardly inflammable, self-extinguishing
- Material, knurls
- Zinc die-cast, nickel-plated
- Sealing material
- NBR
Ambient conditions
- Ambient temperature (operation)
- -25 °C - 90 °C (Plug / socket)
- Degree of protection
- IP65
- Degree of protection
- IP67
Environmental Product Compliance
- China RoHS
- Environmentally friendly use period: unlimited = EFUP-e
- China RoHS
- No hazardous substances above threshold values
Standards and Regulations
- Flammability rating according to UL 94
- V0
Cable
- Cable type
- INTERBUS
- Cable type (abbreviation)
- 900
- Cable structure
- 3 x 2 x 0.22 mm²
- Conductor cross section
- 3x 2x 0.22 mm²
- AWG signal line
- 24
- Conductor structure signal line
- 32x 0.10 mm
- Wire colors
- Green-yellow, white-brown, gray-pink
- Twisted pairs
- 2 cores to the pair
- Overall twist
- 3 pairs to the core
- Shielding
- Braided copper wires
- External sheath, color
- may green RAL 6017
- External cable diameter D
- 8 mm
- Minimum bending radius, fixed installation
- 7.5 x D
- Minimum bending radius, flexible installation
- 15 x D
- Number of bending cycles
- 5000000
- Bending radius
- 120 mm
- Traversing path
- 10 m
- Traversing rate
- 1.6 m/s
- Acceleration
- 3.2 m/s²
- Cable weight
- 70 kg/km
- Outer sheath, material
- PUR
- Material conductor insulation
- PE
- Conductor material
- Bare Cu litz wires
- Insulation resistance
- ≥ 5 GΩ*km
- Loop resistance
- ≤ 159.80 Ω/km
- Cable capacity
- ≤ 60 nF/km (At 800 Hz)
- Wave impedance
- 120 Ω ±20 % (at 64 kHz)
- Wave impedance
- 100 Ω ±15 % (with 1 MHz)
- Near end crosstalk attenuation (NEXT)
- ≥ 61 dB (at 772 kHz)
- Near end crosstalk attenuation (NEXT)
- ≥ 59 dB (with 1 MHz)
- Near end crosstalk attenuation (NEXT)
- ≥ 55 dB (at 2 МHz)
- Near end crosstalk attenuation (NEXT)
- ≥ 50 dB (at 4 МHz)
- Near end crosstalk attenuation (NEXT)
- ≥ 46 dB (at 8 МHz)
- Near end crosstalk attenuation (NEXT)
- ≥ 44 dB (at 10 MHz)
- Near end crosstalk attenuation (NEXT)
- ≥ 41 dB (at 16 MHz)
- Near end crosstalk attenuation (NEXT)
- ≥ 40 dB (at 20 МHz)
- Attenuation
- ≤ 15 dB/km (at 256 kHz)
- Attenuation
- ≤ 24 dB/km (at 772 kHz)
- Attenuation
- ≤ 27 dB/km (with 1 MHz)
- Attenuation
- ≤ 52 dB/km (at 4 МHz)
- Attenuation
- ≤ 84 dB/km (at 10 MHz)
- Attenuation
- ≤ 112 dB/km (at 16 MHz)
- Attenuation
- ≤ 119 dB/km (at 20 МHz)
- Signal speed
- 0.66 c
- Coupling resistance
- < 250.00 mΩ/m (at 30 MHz)
- Nominal voltage, cable
- 250 V (Peak value, not for high-power applications)
- Test voltage Core/Core
- 1500 Vrms
- Test voltage Core/Shield
- 1000 Vrms
- Flame resistance
- according to VDE 0472, Part 4, test type B
- Flame resistance
- according to IEC 60332-1
- Ambient temperature (operation)
- -40 °C - 80 °C (cable, fixed installation)
- Ambient temperature (operation)
- -30 °C - 70 °C (cable, flexible installation)