Distributed I/O device - AXL E ETH IOL8 DI4 M12 6M - 2701541
2701541
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Oferta con plazo de entrega del fabricante
Entrega:1 - 2 días laborables
El mejor precio:
€448.83

Additional Information

Part Number
2701541
UPC
4046356763899
Country of Origin
DE
ETIM
Group Code : EG000024
Group Description : PLC's
Class Description : Fieldbus, decentr. periphery - digital I/O module
Class Code : EC001599
Version : 7

Axioline potentials

Protective circuit
Surge protection of the supply voltage electronic (35 V, 0.5 s)
Protective circuit
Polarity reversal protection of the supply voltage parallel diode; with external 5 A fuse (only for commissioning)
Protection
max. 8 A (polarity reversal protection up to 5 A)

Note

Utilization restriction
EMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width
60 mm
Height
185 mm
Depth
38 mm
Note on dimensions
The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
Drill hole spacing
198.5 mm

System limits of the bus coupler

Designation
Modbus/TCP
Equipment type
Modbus slave (server)
System-specific protocols
Modbus protocols Modbus/TCP
Protocols supported
SNMP v1
Protocols supported
HTTP
Protocols supported
TFTP
Protocols supported
FTP
Protocols supported
BootP
Protocols supported
DHCP
Specification
Modbus application protocol V1.1b

Supply

Designation
Module electronics and sensors (US)
Connection method
M12 connector (T-coded)
Number of positions
4
Supply voltage
24 V DC
Supply voltage range
19.5 V DC - 31.2 V DC (including all tolerances, including ripple)
Current consumption
typ. 180 mA ±15 % (at 24 V DC)
Designation
Actuators (UA)
Supply voltage range
18 V DC - 31.2 V DC (including all tolerances, including ripple)
Current consumption
typ. 28 mA ±15 % (at 24 V DC)

Digital inputs

Input name
Digital inputs at pin 2 for type A ports
Description of the input
IEC 61131-2 type 1
Connection method
M12 connector, X01 - X04 have double occupancy
Connection technology
3-wire
Number of inputs
4
Protective circuit
Overload protection, short-circuit protection of sensor supply
Nominal input voltage UIN
24 V DC
Nominal input current at UIN
typ. 3 mA
Input filter time
< 1000 µs
Description of the input
IO-Link ports in digital input (DI) mode
Number of inputs
max. 8 (EN 61131-2 type 1)
Input voltage range "0" signal
-0.3 V DC - 5 V DC
Input voltage range "1" signal
15 V DC - 30 V DC
Nominal input current
typ. 3 mA
Sensor current per channel
max. 200 mA (from L+/L-)
Total sensor current
max. 1.6 A (from L+/L-)
Input frequency
0.5 kHz
Type of protection
Overload protection
Type of protection
Short-circuit protection for the sensor supply

Ambient conditions

Ambient temperature (operation)
-25 °C - 60 °C
Ambient temperature (storage/transport)
-25 °C - 85 °C
Permissible humidity (operation)
5 % - 95 %
Permissible humidity (storage/transport)
5 % - 95 %
Air pressure (operation)
70 kPa - 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa - 106 kPa (up to 3000 m above sea level)
Degree of protection
IP65/IP67

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 25;
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Electrical isolation

Test section
24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
Test section
24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min.
Test section
24 V supply (communications power and sensor supply, IO-Link ports)/FE 500 V AC 50 Hz 1 min.
Test section
Bus connection (Ethernet 1)/FE 500 V AC 50 Hz 1 min.
Test section
Bus connection (Ethernet 2)/FE 500 V AC 50 Hz 1 min.
Test section
Bus connection (Ethernet 1)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min.
Test section
24 V supply (actuator supply)/24 V supply (communications power and sensor supply, IO-Link ports) 500 V AC 50 Hz 1 min.
Test section
24 V supply (actuator supply)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
Test section
24 V supply (actuator supply)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min.
Test section
24 V supply (actuator supply)/FE 500 V AC 50 Hz 1 min.

Digital outputs

Output description
IO-Link ports in digital output (DO) mode
Connection method
M12 connector, X01 - X04 have double occupancy
Connection technology
3-wire
Number of outputs
max. 8
Nominal output voltage
24 V DC
Maximum output current per channel
150 mA
Maximum output current per device
1.2 A
Nominal load, ohmic
3.6 W (160 Ω, at nominal load)
Nominal load, inductive
3.6 VA (0.8 H, 160 Ω, at nominal load)
Signal delay
max. 150 µs (when switched on)
Signal delay
max. 200 µs (when switched off)
Switching rate
1 per second, maximum (at nominal inductive load)
Limitation of the voltage induced on circuit interruption
-15 V DC
Output voltage when switched off
max. 1 V
Output current when switched off
max. 300 µA
Type of protection
Overload protection
Type of protection
Short-circuit protection
Behavior with overload
Shutdown with automatic restart

Interfaces

Designation
Ethernet
No. of channels
2
Connection method
M12 fast connection technology
Note on the connection method
D-coded
Designation connection point
Copper cable
Transmission speed
10/100 Mbps (with auto negotiation)
Number of positions
4

Standards and Regulations

Mechanical tests
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Mechanical tests
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse
Mechanical tests
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)

Modelos CAD

Rastrear piezas
Rastrear piezas
Descargar