Termination board 2719962
2719962
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
€42.15
1
Formas de pago:
Un total de 29 Parts In-Stock de 13 Distributors
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
Enviar solicitud de precio

Additional Information

Part Number
2719962
UPC
4017918140311
Country of Origin
DE

Software interfaces

Application interface
S7 I/O driver
Application interface
S7 function blocks

Note

Utilization restriction
EMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width
50 mm
Height
290 mm
Depth
210 mm

Control system

Control system
SIMATIC® S7-400 controllers
Engineering tool
STEP 7 from version 5.x
Diagnostics tool
DIAG+ from version 1.0x
Configuration tool
CMD from Version 4.0x

Ambient conditions

Degree of protection
IP20
Ambient temperature (operation)
0 °C - 60 °C
Ambient temperature (storage/transport)
-25 °C - 65 °C
Permissible humidity (operation)
30 % (up to 75 %, without condensation)
Permissible humidity (storage/transport)
30 % (up to 95 %, no condensation)
Air pressure (operation)
860 hPa - 1080 kPa (up to 1500 m above sea level)
Air pressure (storage/transport)
660 hPa - 1080 kPa (up to 3500 m above sea level)

Environmental Product Compliance

China RoHS
Environmentally Friendly Use Period = 50
China RoHS
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Software requirements

Configuration tool
CMD from Version 4.0x
Configuration tool
Config+ from version 1.00 onwards
Diagnostics tool
DIAG+ from version 1.0x
Programming tool
STEP 7 from version 5.x

Standards and Regulations

Connection in acc. with standard
CUL

Fieldbus function

Amount of process data
max. 8192 Bit
Number of supported devices
max. 128 (of which 254 are remote bus devices/bus segments)
Number of devices with parameter channel
max. 126 (512 words)

Data interfaces

Interface
Control system
Connection method
SIMATIC® S7-400 P-Bus
Transmission speed
500 kbps / 2 Mbps (can be switched)
Interface
INTERBUS remote bus
Connection method
9-pos. D-SUB socket strip
Transmission speed
500 kbps / 2 Mbps500 kbps 2 Mbps (can be switched)
Interface
Parameterization/operation/diagnostics
Connection method
RS-232-C, D-SUB male connector
Interrupts
Are supported

Power supply

Power supply connection
Via SIMATIC I/O bus
Typical current consumption
0.9 A
Supply voltage
5 V DC
Power dissipation
max. 4.5 W