Activo maduro
This product is part of the Nema Pressure Switches range, an offer of pressure switches, vacuum switches and float switches. This float switch is a type of level sensor, a device used to detect the level of liquid within a tank. It has 2 normally closed, DPDT-DB (double pole double throw, double break) form YY, snap action contacts. This float switch has 4inch to 31inch adjustable float movement by any position. It is furnished with screw clamp terminals for electrical connection and two 22.35mm cable entries with 0.84inch across flats. This open tank pedestal style float switch has a vertical rod angle with vertical operating position only. It offers mechanical durability of about 300 cycles and electrical durability of about 100 cycles. It is a NEMA 1 rated product. The enclosure is made of polypropylene. It weighs 0.95kg. As a market leader, providing a variety of well-known devices and a long history of application success, switches provide virtually unlimited flexibility and an unmatched level of reliability. A comprehensive range of pressure switches compliant with US and international standards, such as NEMA, UL, CSA and IEC.
Country of Origin
MX
Part Number
9036FG
Tariff Code
8536509065
UPC
785901330790
UNSPSC
39122219
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Solicite un presupuesto y le enviaremos información sobre disponibilidad y precio.

Specifications

Range Of Product
Square D Pumptrol
Product Specific Application
liquid level control
Quantity Per Set
set of 1
Electrical Circuit Type
power circuit
Product Or Component Type
float switch
Type Of Packing
individual
Device Application
open tank pedestal style
Device Short Name
9036FG

Contractual warranty

Warranty
18 months

Complementary

Cable Entry Number
2 0.88 in cable entries with 0.84 in across flats UL 508
Electrical Connection
screw-clamp terminals 10 AWG
Contact Operation
contacts close on liquid rise
Product Destination
for open tank or sump
Terminal Block Type
4 terminals
Terminals Description Iso N°1
line-load-load-line
[Ui] Rated Insulation Voltage
575 V UL 508
Short-Circuit Protection
20 A cartridge fuse gG
Controlled Fluid
fresh water specific gravity of 0.85 in or higher || sea water specific gravity of 0.85 in or higher || hydraulic oil specific gravity of 0.85 in or higher || corrosive fluid specific gravity of 0.85 in or higher
Device Mounting
pedestal
Force Up To Trip
16 ozf
Mechanical Durability
300 cycles
Force Down To Trip
16 ozf
Float Rod Angle
vertical
Factory Modification
without
Float Movement
4...31 in adjustable
Operating Position
vertical position only
Enclosure Material
polypropylene or equivalent
Maximum Operating Rate
60 cyc/mn
Local Signalling
without
Contacts Type And Composition
2 NC, snap action, DPST-DB, Form YY
Motor Power Kw
1.5 kW 2 hp)115 V AC, 1 phase || 2.2 kW 3 hp)115 V AC, 3 phase || 2.2 kW 3 hp)230 V AC, 1 phase || 3.7 kW 5 hp)230 V AC, 3 phase || 0.75 kW 1 hp)460 V AC, 3 phase || 0.75 kW 1 hp)475 V AC, 3 phase || 0.18 kW 0.25 hp)32 V DC || 0.37 kW 0.5 hp)115 V DC || 0.37 kW 0.5 hp)230 V DC
Materials In Contact With Fluid
nylon || aluminium || zinc plated steel or equivalent || polystyrene
Float Position
any
Net Weight
2.1 lb(US)
Kit Composition
float switch || float || rod
Electrical Durability
100 cycles 60 cyc/mn

Offer Sustainability

Circularity Profile
ENVEOLI111210EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111211EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
UL listed file E12158 || CSA file LR25490
Ambient Air Temperature For Operation
-22-220 °F
Ambient Air Temperature For Storage
-22-220 °F
Standards
CE || UL 508
Nema Degree Of Protection
NEMA 1 UL 50

Documentos

Data Sheet

Descargar